All Days 2009
DOI: 10.2523/iptc-13164-ms
|View full text |Cite
|
Sign up to set email alerts
|

Three Dimensional Numerical Analysis of Fluid Flow through Fractured Rock Core Using X-Ray Computed Tomography

Abstract: TX 75083-3836, U.S.A., fax +1-972-952-9435. AbstractA three dimensional numerical modeling coupled with X-ray Computed Tomography (CT) for fracture flow was applied to fractured granite core samples. One of the samples had an artificial single fracture, and the others had natural multiple fractures. A relationship between CT value and fracture aperture (fracture aperture calibration curve) was obtained by X-ray CT scanning for a fracture aperture calibration standard with varying the aperture from 0.1 to 0.5 m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 23 publications
0
1
0
Order By: Relevance
“…Finally, the samples were scanned by a CT scanner (Neuro-Logica Corporation, CereTom) to detect the fractures with a resolution of 0:5 mm × 0:5 mm × 0:625 mm and a single exposure time of 0.5 s. The three-dimensional gray-scale images were processed by collecting the X-ray attenuation information to obtain the segmentation image via Avizo software that could be utilized for fracture network modeling. Then, the fracture information was extracted based on the ball-stick model to reveal the spatial distribution of fractures, as shown in Figure 5 [39,46]. Especially, note that the fractures with smaller widths should not be in the study since the sample heating will produce some fractures.…”
Section: Geofluidsmentioning
confidence: 99%
“…Finally, the samples were scanned by a CT scanner (Neuro-Logica Corporation, CereTom) to detect the fractures with a resolution of 0:5 mm × 0:5 mm × 0:625 mm and a single exposure time of 0.5 s. The three-dimensional gray-scale images were processed by collecting the X-ray attenuation information to obtain the segmentation image via Avizo software that could be utilized for fracture network modeling. Then, the fracture information was extracted based on the ball-stick model to reveal the spatial distribution of fractures, as shown in Figure 5 [39,46]. Especially, note that the fractures with smaller widths should not be in the study since the sample heating will produce some fractures.…”
Section: Geofluidsmentioning
confidence: 99%