2019
DOI: 10.1016/j.bios.2019.01.019
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional drivable optrode array for high-resolution neural stimulations and recordings in multiple brain regions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 46 publications
0
7
0
Order By: Relevance
“…A drivable part which can lead the probe tip to break through the wrap and continue to function becomes a good choice. The drivable optoprobes are inspired by the micro-actuated structure of the electrodes [ 118 , 119 ], which can be customized according to the different optical components ( Figure 3 a,b) [ 97 , 116 ] or simpler 3D-printed molds [ 120 , 121 , 122 ]. The 3D-printed mold can also precisely control the adjustment step by twisting of the screw, shown in Figure 3 c, and the minimum step is as low as 320 μm [ 122 ].…”
Section: Optoprobesmentioning
confidence: 99%
“…A drivable part which can lead the probe tip to break through the wrap and continue to function becomes a good choice. The drivable optoprobes are inspired by the micro-actuated structure of the electrodes [ 118 , 119 ], which can be customized according to the different optical components ( Figure 3 a,b) [ 97 , 116 ] or simpler 3D-printed molds [ 120 , 121 , 122 ]. The 3D-printed mold can also precisely control the adjustment step by twisting of the screw, shown in Figure 3 c, and the minimum step is as low as 320 μm [ 122 ].…”
Section: Optoprobesmentioning
confidence: 99%
“…For example, fMRI provides an excellent aid for the study of psychiatric disorders [ 3 , 4 ]. However, for dynamic observation of neuronal and synaptic activities at the single-cell level down to molecular scales, craniotomy experiments are frequently required for implantation of cortical and deep-brain electrodes or electrode arrays [ 17 , 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 ]. For two-photon experiments and fluorescence measurements, cranial surgery is also performed in installation of many novel brain-computer-interfaces (BCIs) [ 27 , 28 , 29 , 30 , 31 , 32 , 33 ].…”
Section: Introductionmentioning
confidence: 99%
“…Meanwhile, the implantable BCI has expanded many functional features, including the modulation of neural activities by light, electrical and magnetic stimulation, and drug delivery via microfluidics to achieve local control or treatment [17][18][19][20][21][22][23][24][25][26][27][28][29][30][31]. Most of the existing BCI devices are rigid, such as the Utah electrode arrays, Michigan probes and Pt-Ir microwire electrodes [17,[32][33][34][35][36][37][38][39][40][41]. The Utah electrode array shows the characteristics of high density, compact layout and reliability, which can collect hundreds of neural signals synchronously.…”
Section: Introductionmentioning
confidence: 99%