2010
DOI: 10.1007/s11547-010-0511-6
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional analysis of pulmonary nodules: variability of semiautomated volume measurements between different versions of the same software

Abstract: There is variability also in the results provided by different versions of the same volumetric software, and this may affect the calculation of the nodule-doubling time. Computer-aided assessment of the growth of lung nodules should always be performed using the same version of volumetric software and the same segmentation algorithm.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(10 citation statements)
references
References 21 publications
0
10
0
Order By: Relevance
“…Manual correction it is expected to act on these biases [55,115]. Differences in volume estimation have been reported when using different software and different algorithms of correction of partial volume effect artefacts [57,67,[116][117][118]. Therefore, it is advisable to perform nodule follow-up using the same scanner, technique and software package.…”
Section: Factors Influencing Nodule Measurement Variationsmentioning
confidence: 99%
“…Manual correction it is expected to act on these biases [55,115]. Differences in volume estimation have been reported when using different software and different algorithms of correction of partial volume effect artefacts [57,67,[116][117][118]. Therefore, it is advisable to perform nodule follow-up using the same scanner, technique and software package.…”
Section: Factors Influencing Nodule Measurement Variationsmentioning
confidence: 99%
“…Factors considered in these studies include nodule characteristics such as size [147, 204, 269, 303, 329, 330], shape [269, 330], and appearance types of solidness [273]; pulmonary deformation due to cardiovascular motion [331] and inspiration [269]; CT reconstruction parameters such as slice thickness [164, 204, 304, 329, 330, 332], slice intervals [164, 204, 304, 332], field of views [164, 204, 304, 332], algorithm types [146, 164, 332], kernel types [273, 304], tube current time [146, 164], and dosage settings [271]; CT scanner vendors [303]; segmentation performance due to choices of threshold parameters in a segmentation algorithm [204, 248], segmentation algorithms [146, 248, 302, 333], segmentation algorithms in the same segmentation software package [272], segmentation software packages [274], and versions of a segmentation software package [270]; intra- and interobserver variations by using a commercial software package for semi-automatic nodule segmentation and volumetry [165, 202, 269]; levels of observer's experience and training [302]. …”
Section: Diagnosis Of Lung Nodulesmentioning
confidence: 99%
“…When nodule size is determined volumetrically, the same software version and segmentation algorithm is recommended at follow-up examinations to avoid measurement inaccuracy [ 51 , 52 , 56 ] .…”
Section: Ldct: Nodule Measurementmentioning