2021
DOI: 10.1016/j.cej.2021.128775
|View full text |Cite
|
Sign up to set email alerts
|

Thorough computational analysis of the staggered herringbone micromixer reveals transport mechanisms and enables mixing efficiency-based improved design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 36 publications
(16 citation statements)
references
References 71 publications
0
13
0
Order By: Relevance
“…A structure that was wider than it was tall and having a large surface area in contact with the wafer would be much stronger and last longer. An ideal solution to this problem was to use a staggered herringbone mixer, which uses a wide channel (400 μm) with specially shaped herringbone grooves on the top. , The schematic of the microfluidic device is shown in Figure , which also shows the design and features of the chevron-shaped perturbations fabricated into the device. In the lower part of Figure , the physical device can be seen with the inflow and outflow channels marked categorically.…”
Section: Resultsmentioning
confidence: 99%
“…A structure that was wider than it was tall and having a large surface area in contact with the wafer would be much stronger and last longer. An ideal solution to this problem was to use a staggered herringbone mixer, which uses a wide channel (400 μm) with specially shaped herringbone grooves on the top. , The schematic of the microfluidic device is shown in Figure , which also shows the design and features of the chevron-shaped perturbations fabricated into the device. In the lower part of Figure , the physical device can be seen with the inflow and outflow channels marked categorically.…”
Section: Resultsmentioning
confidence: 99%
“…It derives that, especially for high Pe number, an insufficient mesh resolution could lead to artificial or inaccurate results of COMSOL. A recommended way of calibrating the mesh to gain the right balance between performance and numerical stability can be found in Hadjigeorgiou et al 65 .…”
Section: Resultsmentioning
confidence: 99%
“…42 That is the reason why a micromixer was designed for the chip. To fully and rapidly mix the cell suspension and the hypertonic solution, many micromixers can be used, such as the Tesla micromixer, 43 the staggered herringbone micromixer, 44 and the fishhook-shaped micromixer. 45 In this study, we adopted the chaotic micromixer proposed by Stroock et al, 33 which meets the requirements of mixing and also makes the chip as small as possible.…”
Section: Discussionmentioning
confidence: 99%