1997
DOI: 10.1016/s0003-4975(96)00945-9
|View full text |Cite
|
Sign up to set email alerts
|

Thirty-Year Results of Starr-Edwards Prostheses in the Aortic and Mitral Position

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
46
0
3

Year Published

2002
2002
2013
2013

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(49 citation statements)
references
References 15 publications
0
46
0
3
Order By: Relevance
“…Prosthesis type as a TE predictor is controversial. 4,7,12,34,42,43 These uncertainties stem mostly from differences in TE definition between centers, 5 and uniform TE definition may be an advantage of single-center studies. Recent prostheses are considered less thrombogenic than first-generation prostheses.…”
Section: Effect Of Prosthesis Typementioning
confidence: 99%
“…Prosthesis type as a TE predictor is controversial. 4,7,12,34,42,43 These uncertainties stem mostly from differences in TE definition between centers, 5 and uniform TE definition may be an advantage of single-center studies. Recent prostheses are considered less thrombogenic than first-generation prostheses.…”
Section: Effect Of Prosthesis Typementioning
confidence: 99%
“…These rates of each valve type were almost similar to the previous reports. 4,18 Valve dysfunction because of cloth wear and pannus overgrowth was more extensive than expected based on the reoperations. Clinical manifestations of heart failure, such as increasing dyspnea during exercise, edema of the extremities, disappeared after reoperation, especially in patients who underwent valve replacement more than 20 years ago.…”
Section: Discussionmentioning
confidence: 88%
“…1,2,4 The cloth-covered model of the S-E stellite-ball valve was introduced to eliminate the larger metal surface and ball variance in the original silastic ball prosthesis, with the intention of reducing thromboembolism. The fabric extension was extended from the inflow orifice to the cage (model 2300 and model 6300), and composite seat prosthesis (model 2310 and model 6310), which featured small metallic studs around the orifice was introduced, resulting in the protection of the orifice cloth on valve closure.…”
Section: Discussionmentioning
confidence: 99%
“…Otra consideración importante que se desprende de este estudio es que, siendo la severidad de los síntomas y el deterioro de la función ventricular factores que elevan la mortalidad operatoria y disminuyen la supervivencia alejada, debiéramos indicar el reemplazo valvular más precozmente, como lo establecen las actuales guías de la ACC/ AHA 33 y lo reportan autores recientes 15,34 . En cuanto a la prótesis usada, estudios multicéntricos y prospectivos no han mostrado diferencias significativas entre los diferentes tipos de prótesis con respecto a mejoría sintomática, incidencia de complicaciones y supervivencia alejada 2,27,35,36 . Nosotros decidimos utilizar una prótesis mecánica en vez de biológica, dada la edad y la alta incidencia de fibrilación auricular de nuestra serie.…”
Section: Discussionunclassified