2005
DOI: 10.1115/1.1993662
|View full text |Cite
|
Sign up to set email alerts
|

Thin-Film Coupled Fluid-Solid Analysis of Flow Through the Ahmed™ Glaucoma Drainage Device

Abstract: The Ahmed glaucoma valve (AGV) is a popular glaucoma drainage device, allowing maintenance of normal intraocular pressure in patients with reduced trabecular outflow facility. The uniquely attractive feature of the AGV, in contrast to other available drainage devices, is its variable resistance in response to changes in flow rate. As a result of this variable resistance, the AGV maintains a pressure drop between 7 and 12 mm Hg for a wide range of aqueous humor flow rates. In this paper, we demonstrate that the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0
3

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 8 publications
1
4
0
3
Order By: Relevance
“…The Young's modulus of the commercially purchased PLC was noted to be 32.5 MPa before degradation, which is higher than the reported value of 12 MPa due to differences in synthesis 23. The Young's modulus of Si was found to be 4 ± 0.3 MPa, which is close to the reported value of 5 MPa 24. Figure 5d shows a plot of Young's modulus against time for PLC films during the degradation study.…”
Section: Resultssupporting
confidence: 61%
See 1 more Smart Citation
“…The Young's modulus of the commercially purchased PLC was noted to be 32.5 MPa before degradation, which is higher than the reported value of 12 MPa due to differences in synthesis 23. The Young's modulus of Si was found to be 4 ± 0.3 MPa, which is close to the reported value of 5 MPa 24. Figure 5d shows a plot of Young's modulus against time for PLC films during the degradation study.…”
Section: Resultssupporting
confidence: 61%
“…Thus, any biodegradable material chosen to perform within the AGV must satisfy the following requirements: a) it must be elastomeric, that is, it must be easily stretched and be able to maintain the strain for a specified period (4–6 weeks); this implies minimal creep or stress relaxation in this time period. b) Its modulus should be in the region of 5–10 MPa, based on the silicone modulus 15. c) Its biodegradation rate must be such that substantial relaxation occurs in 4–6 weeks, which is the period associated with capsule formation in vivo.…”
Section: Introductionmentioning
confidence: 99%
“…5,6 × 10 −3 mmHg/µl • min −1 (iStent ® inject) vorliegt [26]. Auch das Membranventil des Ahmed™ GDI wurde bereits mithilfe von FSI-Analysen untersucht [21][22][23]. Die beschriebenen numerischen Modelle ermöglichen eine Untersuchung der nicht linearen Volumenstrom-Druckdifferenz-Charakteristik des Implantats.…”
Section: Fsi-analyseunclassified
“…Im Rahmen von Parameterstudien, z. B. durch Variation des Membranmaterials, der Membrandicke oder -länge, kann so die Einstellung einer gewünschten Volumenstrom-Druckdifferenz-Charakteristik realisiert werden [21,22]. Das im Rahmen der vorliegenden Arbeit beschriebene numerische Modell ermöglicht eine wechselseitig gekoppelte FSI-Analyse dreidimensionaler mikromechanischer Ventilmodelle für GDI.…”
Section: Fsi-analyseunclassified
See 1 more Smart Citation