2004
DOI: 10.1007/s00216-003-2426-8
|View full text |Cite
|
Sign up to set email alerts
|

Thick-film electrodes for measurement of superoxide and hydrogen peroxide based on direct protein?electrode contacts

Abstract: Cytochrome c was immobilized on screen-printed thick-film gold electrodes by a self-assembly approach using mixed monolayers of mercaptoundecanoic acid and mercaptoundecanol. Cyclic voltammetry revealed quasi-reversible electrochemical behavior of the covalently fixed protein with a formal potential of +10 mV vs. Ag/AgCl. Polarized at +150 mV vs. Ag/AgCl the electrode was found to be sensitive to superoxide radicals in the range 300-1200 nmol L(-1). Compared with metal needle electrodes sensitivity and reprodu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
23
0
1

Year Published

2006
2006
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 28 publications
(24 citation statements)
references
References 23 publications
0
23
0
1
Order By: Relevance
“…This means that cytochrome c is only an electron transfer protein, while P450 in reduced form can bind oxygen [2,3]. Besides, cytochrome c may be used in such a bienzyme system as antioxidant and counter agent for hydrogen peroxide or superoxide anion radicals [50]. Catalytic behaviour of the DDAB/Au/P450 2B4 electrodes was studied by CV, SWV, and amperometry.…”
Section: Resultsmentioning
confidence: 99%
“…This means that cytochrome c is only an electron transfer protein, while P450 in reduced form can bind oxygen [2,3]. Besides, cytochrome c may be used in such a bienzyme system as antioxidant and counter agent for hydrogen peroxide or superoxide anion radicals [50]. Catalytic behaviour of the DDAB/Au/P450 2B4 electrodes was studied by CV, SWV, and amperometry.…”
Section: Resultsmentioning
confidence: 99%
“…A number of highly sensitive electrochemical biosensors for detection of free oxygen radicals and antioxidants have been reported. [7][8][9][10][11] They are based on the use of immobilized redox proteins, especially cytochrome C, which is easily reduced by the oxygen radicals, and typical catalytic currents can be measured. All these protein-based biosensors suffer from a limited stability, and their preparation is rather time consuming.…”
mentioning
confidence: 99%
“…Thus, SOD electrodes have the inherent advantage of a higher sensitivity. In addition, SOD does not show a pseudoperoxidase activity as reported for cyt.c [12,21], which may falsify the biosensors signal if not carefully controlled. SOD is very selective for superoxide providing the basis for a very specific sensor.…”
Section: Introductionmentioning