2012
DOI: 10.1021/je300108z
|View full text |Cite
|
Sign up to set email alerts
|

Thermophysical Properties of Ammonium-Based Bis{(trifluoromethyl)sulfonyl}imide Ionic Liquids: Volumetric and Transport Properties

Abstract: Density, rheological properties, and conductivity of a homologous series of ammonium-based ionic liquids N-alkyl-triethylammonium bis{(trifluoromethyl)sulfonyl}imide were studied at atmospheric pressure as a function of alkyl chain length on the cation, as well as of the temperature from (293.15 to 363.15) K. From these investigations, the effect of the cation structure was quantified on each studied properties, which demonstrated, as expected, a decrease of the density and conductivity, a contrario of an incr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

11
47
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 70 publications
(58 citation statements)
references
References 27 publications
11
47
0
Order By: Relevance
“…28 The V m of each IL at 298.15 K was determined based on the experimental density data taken from the literature. [37][38][39] As shown in Fig. 4, the sulfonium-based ILs fall close to the correlation previously presented for a wide range of [NTf 2 ]-based ILs.…”
Section: Temperature Dependence Of the Water Solubility In Ilssupporting
confidence: 88%
“…28 The V m of each IL at 298.15 K was determined based on the experimental density data taken from the literature. [37][38][39] As shown in Fig. 4, the sulfonium-based ILs fall close to the correlation previously presented for a wide range of [NTf 2 ]-based ILs.…”
Section: Temperature Dependence Of the Water Solubility In Ilssupporting
confidence: 88%
“…Analyses of the influence of an IL's constitution on the electrical conductivity of ILs have been already studied in literature . In particular, the influence of the length of alkyl chains in cations and anions is of interest.…”
Section: Resultsmentioning
confidence: 99%
“…The above optimisation model is trained using the training data set only, whose prediction accuracy to unseen ILs is estimated using the test set. Mean absolute percentage error (MAPE) is computed to quantify prediction accuracy, with small values mean that the proposed formula can reliably forecast electrical conductivity of new ILs (See Table for details) …”
Section: Development Of Second‐order Gc Methodsmentioning
confidence: 99%
“…[34] Viscosities were measured on ILs with around 0.5 wt %w ater.I tw as considered that the measured viscosity undervalued the viscosity of the pure IL by at least 20 %. Ac apillary tube with an internal diameter of 1.8 mm was considered to be optimal for viscosities up to 300 MPa s. The density of the fluid was necessary to calculate the viscosity from falling ball experiments.…”
Section: Viscositymentioning
confidence: 99%
“…The density of [N 2226 ][OAc] (0.96063 gcm À3 at 25 8C, with al inear evolution from 25 to 80 8C: density (T [8C]) = 0.97436À0.0005527 T [8C]) was measured by using av ibrating tube densimeter DMA 5000M instrument from Anton Paar.D ensities for the other solvents were calculated from the density of [N 2226 ][OAc] and the molar volume of CH 2 groups of the alkyl chain of 16.92 cm 3 mol À1 . [34] Viscosities were measured on ILs with around 0.5 wt %w ater.I tw as considered that the measured viscosity undervalued the viscosity of the pure IL by at least 20 %. [26] Rheology Cellulose (10 wt %) dissolved in the IL (0.5 g) within few hours at 80 8C.…”
Section: Viscositymentioning
confidence: 99%