1983
DOI: 10.1016/0376-4583(83)90077-8
|View full text |Cite
|
Sign up to set email alerts
|

Thermometric and calorimetric methods in electrochemical and corrosion studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
7
0

Year Published

1989
1989
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(7 citation statements)
references
References 35 publications
0
7
0
Order By: Relevance
“…From the results, one can see when the concentration of Moxifloxacin was increased, the corrosion current density gradually decreased and the inhibition efficiency increased. The nearly steady values of (E corr ) and the decreases of corresponding partial anodic and cathodic current densities, these data show that Moxifloxacin acts as mixed-type inhibitor [43]. Addition of Moxifloxacin has no significant effect on the values of anodic and cathodic Tafel slopes (b a , b c ).…”
Section: Potentiodynamic Polarization Testsmentioning
confidence: 61%
“…From the results, one can see when the concentration of Moxifloxacin was increased, the corrosion current density gradually decreased and the inhibition efficiency increased. The nearly steady values of (E corr ) and the decreases of corresponding partial anodic and cathodic current densities, these data show that Moxifloxacin acts as mixed-type inhibitor [43]. Addition of Moxifloxacin has no significant effect on the values of anodic and cathodic Tafel slopes (b a , b c ).…”
Section: Potentiodynamic Polarization Testsmentioning
confidence: 61%
“…The analytical and electroanalytical techniques are widely used in the determination of ferrous ion and the rate of corrosion of iron in different corrosive medium and at different pH (1)(2)(3)(4)(5)(6)(7)(8)(9). Ferrous ions in aqueous medium result from the iron corrosion, when the iron metal is subjected to corrosive environment, it is directly changed into ferrous ion in the solution and consequently the metal is damaged; the rate of corrosion and metal damaged is determined gravimetrically by the ferrous ion concentration passing into the solution, as the rate of corrosion increases, the concentrations of ferrous ions in the corrosive medium increase and vice versa.…”
Section: Introductionmentioning
confidence: 99%
“…In contrary, only few calorimetric results exist, which explicitly consider chemical reactions preceding or following the electrochemical reaction steps. Among these are calorimetric studies of water formation from the elements [8], hydrogen and oxygen evolution [9,10], formaldehyde oxidation [11], charging and discharging of batteries [12,13] and corrosion [14].…”
Section: Introductionmentioning
confidence: 99%