Thermoluminescence, ESR and x-ray diffraction studies of CaSO4 : Dy phosphor subjected to post preparation high temperature thermal treatment

Abstract: Thermoluminescence (TL), electron spin resonance (ESR) and x ray diffraction studies of CaSO4 : Dy phosphor subjected to post preparation high temperature treatment were carried out. Analysis of the TL glow curve indicated that the dosimetric glow peak at 240 °C reduces, whereas the low temperature satellite peak increases with the increase in the annealing temperature in the range 650–1000 °C. The influence of the annealing atmosphere on the TL glow curve structure was also observed. Reduction of the photolum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
6
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(8 citation statements)
references
References 15 publications
(18 reference statements)
2
6
0
Order By: Relevance
“…These results are also similar to the results already available in the literature[46,53]. As reported earlier[28,45,54], in CaSO4:Eu, Eu exists in the divalent as well as the trivalent state in the CaSO4 lattice and emits fluorescence on both the valency states. The redox reactions in Eu doped CaSO4 phosphor, i.e., conversion of Eu 3+ E 2+ on annealing as well as on irradiation are well known[53].…”
supporting
confidence: 92%
See 1 more Smart Citation
“…These results are also similar to the results already available in the literature[46,53]. As reported earlier[28,45,54], in CaSO4:Eu, Eu exists in the divalent as well as the trivalent state in the CaSO4 lattice and emits fluorescence on both the valency states. The redox reactions in Eu doped CaSO4 phosphor, i.e., conversion of Eu 3+ E 2+ on annealing as well as on irradiation are well known[53].…”
supporting
confidence: 92%
“…The changes in glow curve structures could also take place, however, it is not found that prominent as could be seen from TL glow curves of CaSO4:Eu@600 and CaSO4:Eu@900 samples (if we think that the particles have grown much bigger on annealing at 900 o C than at 600 o C for 2 h). The environment of the luminescent centers and hence glow curve structure could be affected by diffusion of atmospheric oxygen during annealing at much higher temperatures [45]. with respect to the annealing temperature is shown in Fig.…”
Section: Structural Properties Of Caso4:eumentioning
confidence: 99%
“…These lines were attributed to and SO 3 À , SO 4 À and O 3 À radicals respectively. The g values obtained are compared well with those reported in the literature (Mauricio et al, 1996;Sharaf and Hassan, 2004;Gupta et al, 1974;Natarajan et al, 1988;Seshagiri et al, 1988;Bakshi et al, 2008). From Figs.…”
Section: Tl and Epr Studies Of Thermally Sensitized Phosphorsupporting
confidence: 78%
“…Ltd. Hyderabad, India) with a linear heating rate of 2 C per second from room temperature to 300 C. Neutral density filters (Melles Griot BV, Netherlands) of optical densities 3.0 and transmittance 0.01% were used to avoid saturation of Photo Multiplier Tube (PMT). The peak height is vertical length of the peak tip from the temperature axis measured directly from the glow curve (Bakshi et al, 2008;Mathur et al, 1999). Control and irradiated phosphors were stored in dark place at normal laboratory condition when they were not in use.…”
Section: Tl Measurementmentioning
confidence: 99%
“…As any change in the structure of the material can lead to a change in the dosimetry properties, it is essential to study the phase structure from a practical point of view. [11,39,[47][48][49][50][51][52][53] The crystal structure of hydroxyapatite has been studied in several papers, [52,54,55] but its effect on the TL properties of HAP has not yet been investigated. Therefore, in this research work, the aim is to investigate the effect of the crystal structure of HAP on its TL response, using two different synthesis methods, hydrolysis and hydrothermal methods, the effect of annealing temperature, addition of dopants, and other dosimetry behaviour of this substance.…”
mentioning
confidence: 99%