2021
DOI: 10.1016/j.carbpol.2020.117377
|View full text |Cite
|
Sign up to set email alerts
|

Thermoinduced aggegation of chitosan systems in perikinetic and orthokinetic regimes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
15
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(16 citation statements)
references
References 33 publications
1
15
0
Order By: Relevance
“…The rate of sol-gel phase transition of colloidal chitosan systems induced by stochastic Brownian motion was determined using turbidimetric techniques by measuring the values of transmittance T [%] and backscatter BS [%] signals in the entire sample volume [ 21 ]. Examples of experimental curves obtained in subsequent time intervals for a colloidal solution of chitosan acetate with the addition of disodium glycerophosphate are shown in Figure 4 a.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations
“…The rate of sol-gel phase transition of colloidal chitosan systems induced by stochastic Brownian motion was determined using turbidimetric techniques by measuring the values of transmittance T [%] and backscatter BS [%] signals in the entire sample volume [ 21 ]. Examples of experimental curves obtained in subsequent time intervals for a colloidal solution of chitosan acetate with the addition of disodium glycerophosphate are shown in Figure 4 a.…”
Section: Resultsmentioning
confidence: 99%
“…In order to take into account the total changes observed during the formation of the spatial structure, the Turbiscan Stability Index (TSI) parameter was determined, defining the total destabilization of the system, the changes of which can be successfully used to compare the course of the gelation process with the results obtained during rheometric measurements [ 21 ]. Based on the final TSI values ( Figure 7 a), it can be concluded that the greatest changes were observed in the case of the use of magnesium glycerophosphate, and the smallest in the case of the addition of calcium salt.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…200 to over 43,000 s −1 (depending on the needle diameter) or even 55,000 s −1 taking into account the strongly shear-thinned nature of polymer systems. As a consequence, high shear stresses are generated which may affect the spatial conformation of the polymer molecules including their arrangement along the streamlines The previous authors' research [32] has shown that the spatial conformation of biopolymer molecules will strongly depend on the applied shear field, its direction and magnitude.…”
Section: Introductionmentioning
confidence: 99%