Deviation values of specific heat difference DC p ; the Gibbs free energy difference DG; enthalpy difference DH; and entropy difference DS between the supercooled liquid and corresponding crystalline phase produced by the linear, hyperbolic, and Dubey's expressions of DC p and the corresponding experimental values are determined for sixteen bulk metallic glasses (BMGs) from the glass transition temperature T g to the melting temperature T m : The calculated values produced by the hyperbolic expression for DC p most closely approximate experimental values, indicating that the hyperbolic DC p expression can be considered universally applicable, compared to linear and Dubey's expressions for DC p ; which are accurate only within a limited range of conditions. For instance, Dubey's DC p expression provides a good approximation of actual experimental values within certain conditions (i.e., n ¼ DC