Thermodynamic Analysis of G-M/J-T Helium Refrigeration Cycle for a Cryoadsorption Test Facility

Abstract: A cryoadsorption test facility is developing for upgrade the cryopump of EAST neutral beam injector. To provide an optional cryogenic supply plan for the test facility, a Gifford-McMahon (G-M)/Joule-Thomson (J-T) helium refrigeration cycle is designed. In this paper, the influence of stage temperature of two-stages G-M cryocooler and J-T heat exchanger effectiveness on the performance of the cycle is thermodynamically analyzed. The results of the analysis make it clear that, for the cycle precooling power inpu… Show more