2021
DOI: 10.1007/s11804-021-00191-5
|View full text |Cite
|
Sign up to set email alerts
|

Thermodynamic Analysis of a Condensate Heating System from a Marine Steam Propulsion Plant with Steam Reheating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 5 publications
(8 citation statements)
references
References 61 publications
0
3
0
Order By: Relevance
“…In this research, that components are SA and MC. The confirmation of this statement can be found in [64] where is confirmed that in the marine condensate/ feedwater heating system, heater which is the closest to the main condenser (and which operating parameters are the closest to the ambient state) has the lowest exergy efficiency and is highly influenced by the change in the ambient parameters.…”
Section: Figure 5 -Exergy Destruction Of All Components From the Obse...mentioning
confidence: 66%
See 1 more Smart Citation
“…In this research, that components are SA and MC. The confirmation of this statement can be found in [64] where is confirmed that in the marine condensate/ feedwater heating system, heater which is the closest to the main condenser (and which operating parameters are the closest to the ambient state) has the lowest exergy efficiency and is highly influenced by the change in the ambient parameters.…”
Section: Figure 5 -Exergy Destruction Of All Components From the Obse...mentioning
confidence: 66%
“…4. For the specific exergies calculation must be defined the base ambient state [64]. The base ambient state can be selected arbitrarily and is related to the pressure and temperature of the ambient in which observed component or a system operates.…”
Section: Operating Parameters Required For the Waste Heat Recovery Su...mentioning
confidence: 99%
“…Exergy analysis shows different kind of losses in comparison to the energy analysis, therefore the conclusions obtained in energy analysis can strongly differ in regards to exergy analysis conclusions. Moreover, energy analysis of some systems or processes can be practically unusable due to its high dependence on the measurement Pomorski zbornik 62 (2022), 9-30 Thermodynamic Analysis... Vedran Mrzljak, Tomislav Senčić, Igor Poljak, Vedran Medica-Viola equipment accuracy and precision -one example can be found in [58] for a condensate/ feedwater marine heating system.…”
Section: Resultsmentioning
confidence: 99%
“…The same conclusion can be found in the literature [77] for a steam turbines which dominantly operate by using superheated steam. The exergy efficiency of the analyzed steam turbine is low sensitive by the ambient temperature change what significantly differs in comparison to some other components (for example, low pressure condensate heaters) which also uses wet steam for its operation [98].…”
Section: Exergy Analysis During the Ambient Temperature Changementioning
confidence: 96%
“…Also, it was interesting to analyze did a new operating pa-rameters obtained by each algorithm notably influenced steam turbine sensitivity on the ambient temperature change, especially by taking into consideration fact that the dominant operation of any steam turbine from any nuclear power plant is performed with wet (not superheated) steam. As presented in [98], components which operates by using wet steam (in this example, heat exchangers) can be notably influenced by the ambient temperature change. So, the analysis presented in this paper represents a continuation of a previous research with an aim to get a deeper insight into the steam turbine operation after optimization of the whole power plant.…”
Section: Operating Parameters Required For the Observed Steam Turbine Exergy Analysismentioning
confidence: 99%