“…They are appropriate to use (fibers or granules as basic materials) for the microencapsulation of drugs having short biological half-life but frequent administration. It is important the long-term stability of controlled-release dosage forms too [7,[41][42][43][44]. The indiscriminate use of antifungal agents has led to the advancement of microorganisms tolerant to the various drugs used in the market [45].…”
Section: Discussionmentioning
confidence: 99%
“…They are appropriate to use (fibers or granules as basic materials) for the microencapsulation of drugs having short biological half-life but frequent administration. It is important the long-term stability of controlled-release dosage forms too [7,[41][42][43][44]. The indiscriminate use of antifungal agents has led to the advancement of microorganisms tolerant to the various drugs used in the market [45].…”
Section: Discussionmentioning
confidence: 99%
“…Diltiazem hydrochloride (DL) is a benzothiazepine calcium–channel blocker with peripheral and coronary vasodilating effect with limited negative inotropic activity. Its short biological half‐life and thus frequent administration (usually three to four times a day) makes it a potential candidate for sustained or controlled release dosage forms 24. The present study aims at developing newly synthesized (PVA ‐co‐ PAA)/NaCl normal hydrogel (H), hydrogel microspheres (HM) and comparing the antihypertensive activity of DL from two formulations.…”
Section: Introductionmentioning
confidence: 99%
“…[8] The instrument was calibrated using high-purity indium metal as standard. The dynamic scans were taken in nitrogen atmosphere at the heating rate of 10°C/min.…”
Section: Methodsmentioning
confidence: 99%
“…All dynamic differential scanning calorimetry (DSC) studies were carried out on dupont thermal analyzer with 2010 DSC module. [ 8 ] The instrument was calibrated using high-purity indium metal as standard. The dynamic scans were taken in nitrogen atmosphere at the heating rate of 10°C/min.…”
Section: Methodsmentioning
confidence: 99%