Thermo-mechanical stresses distribution on bone drilling: Numerical and experimental procedures

Abstract: In bone drilling, the temperature and the level of stresses at the bone tissue are function of the drilling parameters. If certain thresholds are exceeded, irreversible damages may occur on the bone tissue. One of the main challenges in the drilling process is to control the associated parameters and even more important, to avoid the surrounding tissue damage. In this study, a dynamic numerical model is developed to determine the thermo-mechanical stresses generated during the bone drilling, using the finite e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
27
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(30 citation statements)
references
References 30 publications
3
27
0
Order By: Relevance
“…During the tests, the solid rigid polyurethane foam material was at room temperature and remains equal at the distance where the strain gauges were installed (Fernandes, Fonseca, & Natal, 2017). An order 2 polynomial trendline illustrate the relationship between the drill bit diameter and the maximum stress obtained in the polyurethane foam material.…”
Section: All Experimental Methodology Was Performed In Mechanical Labmentioning
confidence: 99%
See 3 more Smart Citations
“…During the tests, the solid rigid polyurethane foam material was at room temperature and remains equal at the distance where the strain gauges were installed (Fernandes, Fonseca, & Natal, 2017). An order 2 polynomial trendline illustrate the relationship between the drill bit diameter and the maximum stress obtained in the polyurethane foam material.…”
Section: All Experimental Methodology Was Performed In Mechanical Labmentioning
confidence: 99%
“…To define the material model of the solid rigid polyurethane foam should be taken in consideration the strain-rate with dependency of the material plastic curve. Strain rate is accounted for using the Cowper-Symonds model which scales the yield stress by the strain rate dependent factor as shown in equation 1, , (Fernandes, Fonseca, & Natal, 2017). This material model is an elastic-plastic with strain rate dependency and failure, which includes isotropic and kinematic hardening plasticity.…”
Section: Matter: International Journal Of Science and Technology Issnmentioning
confidence: 99%
See 2 more Smart Citations
“…Based on temperature measurements, several studies have been carried out to assess various parameters that influence surgical drilling into bone. 1,12,13,[32][33][34][35][36][37][38][39] However, the complexity of the process and the extensive number of variables involved complicates the statement of concluding remarks. Experimental models coupled to other methodologies, such as computational models, has been a common practice in this type of analysis.…”
Section: Introductionmentioning
confidence: 99%