2021
DOI: 10.1016/j.ijthermalsci.2020.106742
|View full text |Cite
|
Sign up to set email alerts
|

Thermo-hydraulic study in a shell and tube heat exchanger using rod inserts consisting of wire-nails with air injection: Experimental study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…Furthermore, authors are disregarded during their work analysis [25]. The dimensionless augmentation entropy generation number (N s,aug ) is the most frequently utilize criterion, while the EGM criterion has been used to model and optimize HEs design and can be calculated from Equation (14) [20,26].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Furthermore, authors are disregarded during their work analysis [25]. The dimensionless augmentation entropy generation number (N s,aug ) is the most frequently utilize criterion, while the EGM criterion has been used to model and optimize HEs design and can be calculated from Equation (14) [20,26].…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, the Nu was enhanced by 452% for the case of ABI compared with the original case (without ABI). Marzouk et al [14] conducted their experimental study to study the effects of injected air bubbles on the thermo-hydraulic performance of a shell-and-tube-heat exchanger. In their study, the shell fluid volume flow rate was kept constant at 1080 L/h and the tube side volume ranged between 840 and 960 L/h.…”
Section: Introductionmentioning
confidence: 99%
“…The author noticed that the larger slant angle ( α = 20°) and smaller pitch (S = 30 mm) effectively enhance the flow resistance and HT rate. Marzouk et al 68 introduced tube inserts (two inserts with different distances of 10 and 5 cm) inside the tubes of shell and tube HE to enhance the HT performance by employing three different air volumetric flow rates (1, 2, and 3 LPM) and studied the thermal parameters and hydraulic performance. Rahimi et al 69 experimentally and numerically studied friction factor, Nusselt number, and thermal‐hydraulic performance of a tube with three (classic, perforated, notched, and aged twisted tape) different modified twisted tape inserts and compared them with classical insert, the author noticed that 31% improvement in Nusselt number and 22% improvement in aged insert were compared with the classic one.…”
Section: Data Reductionmentioning
confidence: 99%
“…The heat balance deviation necessity be below than 5% and that realized in totally investigational tests. The U can be performed from (Marzouk et al, 2021) :…”
Section: Dimension Redactionmentioning
confidence: 99%