Thermo-economic optimization of RSORC (regenerative solar organic Rankine cycle) considering hourly analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 55 publications
(15 citation statements)
references
References 32 publications
0
15
0
Order By: Relevance
“…To obtain an efficient ORC, the organic fluid should be carefully selected. A number of researches [12][13][14][15][16] have studied the selection of the ORC system. One of the typical recommended organic fluid types used to operate the ORC is R245fa.…”
Section: System Descriptionsmentioning
confidence: 99%
See 1 more Smart Citation
“…To obtain an efficient ORC, the organic fluid should be carefully selected. A number of researches [12][13][14][15][16] have studied the selection of the ORC system. One of the typical recommended organic fluid types used to operate the ORC is R245fa.…”
Section: System Descriptionsmentioning
confidence: 99%
“…A large part of the heat exchanged by the condenser comes from the evaporating water, so an evaporative condenser is mainly a wet bulb sensitive device [22]. The condensing temperature can be calculated by (16), where T wb is the web bulb temperature of the outside air.…”
Section: System Descriptionsmentioning
confidence: 99%
“…ORC were modeled by the means of different supplier in some researches. Regenerative solar ORC as well as ORC for diesel engine waste heat recovery was modeled and optimized by Hajabdollahi et al [21,22]. The design parameters were nominal capacity of diesel engine, diesel operating partial load, evaporator pressure, condenser pressure and refrigerant mass flow rate.…”
Section: Introductionmentioning
confidence: 99%
“…Some studies have been focused on the dynamic model of the SORC. Hajabdollahi et al [13] optimized the RSORC by hourly analysis considering evaporator pressure, condenser pressure, refrigerant mass flow rate, number of solar panel (solar collector), and storage capacity. Bamgbopa et al [14] found that the evaporator and the condenser are critical components of the simplified transient modeling using R245fa.…”
Section: Introductionmentioning
confidence: 99%