2021
DOI: 10.1016/j.optlastec.2021.106995
|View full text |Cite
|
Sign up to set email alerts
|

Thermally stimulated ionic conductivity study of the AgCl – AgBr, AgBr – AgI, AgBr – TlBr0.46I0.54 crystals systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(10 citation statements)
references
References 24 publications
0
7
0
3
Order By: Relevance
“…1, a), that is used to create flat polycrystalline plates. The loading on the sample with area ∼ 78 mm 2 was 6 t [15]. For pressing, the samples were clamped between polished stainless steel plates, and the tooling itself was heated.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…1, a), that is used to create flat polycrystalline plates. The loading on the sample with area ∼ 78 mm 2 was 6 t [15]. For pressing, the samples were clamped between polished stainless steel plates, and the tooling itself was heated.…”
Section: Methodsmentioning
confidence: 99%
“…The measuring circuit contains a rectifier, protective and measuring elements necessary to protect the equipment and ensure multiple repetition of the experiment. During the experiment, a constant current [15] was passed through the plate. The current parameters, namely the current strength and the applied voltage, were recorded using a B7-58 microammeter with a wide measurement range from 1 µA to 10 A and a voltmeter by Mastech with a measurement range from 1 µV up to 600 V, connected to the circuit as shown in Fig.…”
Section: Methodsmentioning
confidence: 99%
“…Измерительная схема содержит выпрямитель, защитный и измерительный элементы, необходимые для защиты оборудования и обеспечения многократного повторения эксперимента. В ходе эксперимента через пластину пропускали постоянный ток [15]. Текущие параметры, а именно сила тока и приложенное напряжение, регистрировали с помощью микроамперметра B7-58 с широким диапазоном измерений от 1 µA до 10 А и вольтметра Mastech с диапазоном измерений от 1 µV до 600 V, подключенных к схеме так, как показано на рис.…”
Section: материалы и методыunclassified
“…2. Предварительный тест этой экспериментальной установки описан авторами в предыдущей статье [15]. Испытания проводили на образцах системы AgCl 0.25 Br 0.75 .…”
Section: материалы и методыunclassified
See 1 more Smart Citation