1956
DOI: 10.6028/jres.057.008
|View full text |Cite
|
Sign up to set email alerts
|

Thermal properties of aluminum oxide from 0 to 1200 K

Abstract: Accurate meas urements of the heat capacity of a-aluminum ox ide (corundum) from 13 0 to 1,170 0 K nrc d escrib ed. An a diabatic calorimeter was used from 13 0 to 380 0 K and a drop method was used with a Bun se n ice calorimeter from 273 0 to 1, 170 0 K . The res ults a rc co mpa red in t he mnge 273 0 to 380 0 K , wh e re t he two methods overlap . From t he d ata, smoo thed values of t he h eat capacity, enthalpy, entropy, and Gibbs free energy from 0 0 to 1,200 0 K are deriv ed a nd tab ul ated.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
76
0
4

Year Published

1968
1968
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 238 publications
(84 citation statements)
references
References 14 publications
(17 reference statements)
4
76
0
4
Order By: Relevance
“…The furna ce, ice calorimeter and th ermome try of this investi gation are very similar to those use d previously in this laboratory for enthalpy meas urem e nts on th e Calorimetry Conference Sample [2]. Howe ver.…”
Section: _1 Calorimeter Propermentioning
confidence: 53%
See 2 more Smart Citations
“…The furna ce, ice calorimeter and th ermome try of this investi gation are very similar to those use d previously in this laboratory for enthalpy meas urem e nts on th e Calorimetry Conference Sample [2]. Howe ver.…”
Section: _1 Calorimeter Propermentioning
confidence: 53%
“…Details desc ribing the preparaLlOn and analysis of th e Calorimetry Confere nce O'-AI~O:1 have already bee n given [2]. Th e ne w O'-AI~O:1 sample (SRM 720) was produce d by th e Linde Air Products Company, as was the Calorimetry Conference Sample.…”
Section: Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…Heat capacity of the sample is obtained after subtracting the copper-cell contribution (see Brunet et al 2004 for the heat capacity of the empty cell). The accuracy of C p measurement is estimated to ±0.8 J mol -1 K -1 based on measurements on a reference compound (a-Al 2 O 3 , Furukawa et al 1956). This accuracy can be converted into an entropy uncertainty (r) of around 1.5% (Brunet et al 2004).…”
Section: Calorimetric Methodsmentioning
confidence: 99%
“…It was essential to modify the Gordon Taylor equation to fit the highest values of the CB/PPy. The parameter k GT in Gordon Taylor equation could be replaced by the polynomial fit equation which describes the dependence of T g on the mass fraction of the component as following: Alternatively, the heat flow rate into the sample is obtained from the following relation [13]: …”
Section: Xrd Measurementmentioning
confidence: 99%