Thermal management and performance enhancement of data centers architectures using aligned/staggered in-row cooling arrangements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 20 publications
0
4
0
Order By: Relevance
“…Air temperatures distributions along the heights of the racks intake and discharge were recorded after maintaining steady state conditions. Details of the experimental setup and procedure can be found in Abbas et al 33 A numerical simulation model of the porotype data center room was also formulated through Ansys-IcePak software for validation. The physical model of the simulation has a typical dimension of the prototype room.…”
Section: Grid Independency Test and Experimental Model Validationmentioning
confidence: 99%
See 2 more Smart Citations
“…Air temperatures distributions along the heights of the racks intake and discharge were recorded after maintaining steady state conditions. Details of the experimental setup and procedure can be found in Abbas et al 33 A numerical simulation model of the porotype data center room was also formulated through Ansys-IcePak software for validation. The physical model of the simulation has a typical dimension of the prototype room.…”
Section: Grid Independency Test and Experimental Model Validationmentioning
confidence: 99%
“…The configuration of having each rack sandwiched between two racks (Configuration C), is not recommended as it needs the largest white area with the smallest occupancy factor of the racks units and at the same time the total costs of the CRACs units is higher than that of configuration B. Accordingly, it can be concluded that configuration B with two cracks units sandwiched between each two CRACs is the optimal configuration as it has the lowest total cost of the CRACs T A B L E 4 CRACs costs of the configurations A, B, and C [32][33][34]…”
Section: Economical Study Of the Three Different Configurationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Their results showed that the servers could have the best thermal performance when they were evenly distributed across the racks. Abbas et al [30] and Nada et al [31] analyzed the influence of the air conditioning alignment and interleaving on the cooling efficiency of the row-based air conditioning DC. They concluded that the cooling effect of the air conditioning units' staggered arrangement in racks could be better than that of aligned arrangement.…”
Section: Introductionmentioning
confidence: 99%