2015
DOI: 10.1109/tia.2014.2358999
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Issues in Operating Large Motors Outside Their Rated Power and Speed Range

Abstract: Because of anticipated occasional hydraulic issues in an oil sands slurry pumping application, it was expected that the existing adjustable speed drive (ASD)-driven 2500-hp motors would be overloaded at up to 3333 hp at a slightly reduced speed from time to time. Working from factory test data, estimates were made of losses and temperature rises at the expected load points. The temperature rises were verified by testing a motor on an ASD using a "back-to-back" ASD/motor arrangement in a specially set up off-si… Show more