2014
DOI: 10.1016/j.expthermflusci.2014.04.009
|View full text |Cite
|
Sign up to set email alerts
|

Thermal instability of a Closed Loop Pulsating Heat Pipe: Combined effect of orientation and filling ratio

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
23
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
2
1

Relationship

2
7

Authors

Journals

citations
Cited by 108 publications
(25 citation statements)
references
References 10 publications
2
23
0
Order By: Relevance
“…When the device is gravity assisted (vertical or bottom heated mode), the flow motion is more vigorous and the thermal performance is higher with respect to the case when the PHP is perfectly horizontal and gravity acceleration is always normal to the main flow path direction [6,7]. It is quite complex to build a PHP, which is gravity-independent on ground, even if some successful attempts of performance independent on orientation have been proposed with threedimensional layouts [8,9].…”
Section: Introductionmentioning
confidence: 95%
“…When the device is gravity assisted (vertical or bottom heated mode), the flow motion is more vigorous and the thermal performance is higher with respect to the case when the PHP is perfectly horizontal and gravity acceleration is always normal to the main flow path direction [6,7]. It is quite complex to build a PHP, which is gravity-independent on ground, even if some successful attempts of performance independent on orientation have been proposed with threedimensional layouts [8,9].…”
Section: Introductionmentioning
confidence: 95%
“…Due to the temperature difference occurs in the two section there is also change in pressure throughout the tube and due to this the phase change occurs. Due to generation and collapsing of bubbles it act as a pumping element for transporting the trapped liquid slug in a oscillating and translating fashion [6]. Due to this the direct consequence of pressure and temperature fluctuations with the fraction distribution.…”
Section: Easy To Design and Manufacturingmentioning
confidence: 99%
“…Due to this the direct consequence of pressure and temperature fluctuations with the fraction distribution. The causes of heat transfer are combination of sensible and latent heat transfer [6]. The sensible heat transfer has the major contribution in the overall heat exchange.…”
Section: Easy To Design and Manufacturingmentioning
confidence: 99%
“…Pulsating heat pipes (PHPs) are becoming a popular technology to address passive thermal management of nuclear, defence and space applications [5][6][7]. The PHP design variants proposed and studied to date, have the potential to meet many of the present and future specific requirements from electronics cooling [8,10], heat recovery [2,15] and passive cooling of reactor containments, to name a few.…”
Section: Introductionmentioning
confidence: 99%