“…The results of Table XI show that the difference between the corrected experimental k eff and the MCNP/MCNPX k eff with one detector model (second row of Table X) is between 400 and 1200 pcm. The statistical error of the corrected k eff is between 180 and 400 pcm, which has been calculated with Equations 10,22,and 23. The present numerical results have been obtained by MCNPX using the fuel composition of the IAEA benchmark specifications, 40,42 which is reported in Table XII. This composition neglects the presence of 234 U and the fuel impurities.…”