/npsi/ctrl?lang=en http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/ctrl?lang=fr Access and use of this website and the material on it are subject to the Terms and Conditions set forth at http://nparc.cisti-icist.nrc-cnrc.gc.ca/npsi/jsp/nparc_cp.jsp?lang=en
NRC Publications Archive Archives des publications du CNRCThis publication could be one of several versions: author's original, accepted manuscript or the publisher's version. / La version de cette publication peut être l'une des suivantes : la version prépublication de l'auteur, la version acceptée du manuscrit ou la version de l'éditeur. Engineering, 5, 1, pp. 83-95, 1993-02 Ranking PVC roofing membranes using thermal analysis Paroli, R. ABSTRACT: The effects of accelerated heat aging on three polyvinyl chloride (PVC) roofing membranes was determined using thermogravimetry (TG), dynamic mechanical thermal analysis (DMA), and tensile testing. The heat aging was done at 100~ and 130~ In general, it was found that the degradation of the reinforced PVC roofing membranes was proportional to the aging temperature and exposure time. Furthermore, it was found that these thermoanalytical techniques can be used to not only record the changes incurred by the samples due to heat aging, but also to provide a ranking of the heat stability of the various materials. The order of stability, using these techniques, was determined to be V1 < V3 < V2, which corresponded with the observed order of stability from actual records obtained on roofs. The results obtained demonstrate that TG and DMA, in conjunction with tensile testing, provide a viable, routine method of evaluating the quality of singleply PVC-based roofing membranes.
Journal of Materials in Civil