2019
DOI: 10.1109/tcpmt.2018.2868049
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Analysis of Water-Cooled Heat Sink for Solid-State Circuit Breaker Based on IGCTs in Parallel

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 13 publications
0
3
0
Order By: Relevance
“…As there are several IGBT modules in this branch, the conduction losses are low for HCBs. Thus, it can be seen that the performance of a typical HCB will be influenced by many factors, e.g., the snubber circuits and stray inductances in the branches, additional bidirectional current interruption capability, a cooling system for an auxiliary dc breaker and so on [51]- [54], and the breaker opening time of HCBs is in the range of 1.2-3 ms [55]. The maximum interruption current reaches 25 kA, as reported in [56].…”
Section: Hybrid Cbsmentioning
confidence: 99%
“…As there are several IGBT modules in this branch, the conduction losses are low for HCBs. Thus, it can be seen that the performance of a typical HCB will be influenced by many factors, e.g., the snubber circuits and stray inductances in the branches, additional bidirectional current interruption capability, a cooling system for an auxiliary dc breaker and so on [51]- [54], and the breaker opening time of HCBs is in the range of 1.2-3 ms [55]. The maximum interruption current reaches 25 kA, as reported in [56].…”
Section: Hybrid Cbsmentioning
confidence: 99%
“…OF PPIS Traditional cooling for HVDC PPI systems requires deionized water flowing through copper heat sinks that are configured in either typical "S" meander or "Archimedes" spiral structures [11]. The heat sink housing is made of copper due to its high electrical and thermal conductivities, which is nickel plated for protection against corrosion.…”
Section: Current Technologies For Thermal Managementmentioning
confidence: 99%
“…The gatherer includes a sun fuelled concentrator, forty silicon cells related in plan, and a multichannel fluid cooling shape with warmth healing limit. In [15], as of late warm investigation of the Integrated Gate-Commutated Thrusters (IGCTs) water-cooled warm temperature sink for the SSCB surveyed for the cadenced improvement of 7.Five kA depicted. They offered the 2 plans of the IGCT water-cooled warmth sink dependent on S-type fluid chamber and the Archimedes winding fluid chamber for the SSCB for the steadfast idea of the paralleled affiliation IGCTs.…”
Section: Related Workmentioning
confidence: 99%