2017
DOI: 10.1109/tcpmt.2017.2696159
|View full text |Cite
|
Sign up to set email alerts
|

Thermal Analysis of Solder Joint Based on Eddy Current Pulsed Thermography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 21 publications
0
7
0
Order By: Relevance
“…Utilization of thermography method for inspection of IC packaging goes back to more than half a century ago [ 88 , 89 , 90 , 91 ], and since then it has been one of the most promising NDT methods to inspect electronic packaging [ 8 , 9 , 92 ]. IRT is used to inspect flip chips [ 93 , 94 ], solder joint defects [ 94 , 95 ], edge defects [ 33 ], misalignment of solder bumps [ 96 ], presence and location of microsolder bumps (as small as approximately 100 µm in diameter and 250 µm in pitch) [ 94 , 97 , 98 ], silicon crack [ 99 ], underfill void [ 99 ], delamination defects with minimum size about 2 µm [ 100 ], and subsurface defects (up to 4 mm in depth) [ 101 ].…”
Section: Ndt Methods For Ic Packagingmentioning
confidence: 99%
See 2 more Smart Citations
“…Utilization of thermography method for inspection of IC packaging goes back to more than half a century ago [ 88 , 89 , 90 , 91 ], and since then it has been one of the most promising NDT methods to inspect electronic packaging [ 8 , 9 , 92 ]. IRT is used to inspect flip chips [ 93 , 94 ], solder joint defects [ 94 , 95 ], edge defects [ 33 ], misalignment of solder bumps [ 96 ], presence and location of microsolder bumps (as small as approximately 100 µm in diameter and 250 µm in pitch) [ 94 , 97 , 98 ], silicon crack [ 99 ], underfill void [ 99 ], delamination defects with minimum size about 2 µm [ 100 ], and subsurface defects (up to 4 mm in depth) [ 101 ].…”
Section: Ndt Methods For Ic Packagingmentioning
confidence: 99%
“…For thermal imaging, the passive method relies on natural heat emitted from the structures or structural components in service without any additional external heat source and the infrared detectors senses thermal radiation [ 102 ]. On the other hand, the active method exerts an external heat to the parts to be inspected using optical [ 8 ], mechanical [ 84 ] or electromagnetic [ 95 ] sources. The external heat creates thermal waves on the surface of the specimen, and the thermal waves reflect back from a defect or anomaly within the object under inspection [ 103 ].…”
Section: Ndt Methods For Ic Packagingmentioning
confidence: 99%
See 1 more Smart Citation
“…Infrared thermography has been used to inspect flip chips to detect solder joint defects in [56,58,63], missing bumps in [57,59,61], cracks and voids in [60,62].…”
Section: Infrared Thermographymentioning
confidence: 99%
“…Although the above control loops introduce some different realization methods of ADPLL and study the performance and locking time of ADPLL, the loop used for induction heating power supply cannot achieve a wide range of frequency sweep and the operating frequency is less than 150 kHz. The frequently used excitation frequency of ECPT [25][26][27][28][29][30] is higher than 150 kHz. This paper presents a resonant frequency tracking loop for full bridge series resonant inverter by switching between DDS and ADPLL.…”
Section: Introductionmentioning
confidence: 99%