2014
DOI: 10.1016/j.enbuild.2014.09.044
|View full text |Cite
|
Sign up to set email alerts
|

Thermal analysis of light pipes for insulated flat roofs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
14
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(14 citation statements)
references
References 19 publications
0
14
0
Order By: Relevance
“…The detailed calculation of linear thermal transmittance in case of contact external peripheral wall and plastic window frame [11] or the impact of freezer room operation on changes of temperature fi eld in subsoil within both steady-state and transient boundary conditions [12] were performed in software CalA. The comparison of results of software CalA and ANSYS Fluent is also performed [13]. This case study is aimed at transient simulation of fl oor heating systems.…”
Section: Calculation Methodsmentioning
confidence: 99%
“…The detailed calculation of linear thermal transmittance in case of contact external peripheral wall and plastic window frame [11] or the impact of freezer room operation on changes of temperature fi eld in subsoil within both steady-state and transient boundary conditions [12] were performed in software CalA. The comparison of results of software CalA and ANSYS Fluent is also performed [13]. This case study is aimed at transient simulation of fl oor heating systems.…”
Section: Calculation Methodsmentioning
confidence: 99%
“…Heat transfer and natural ventilation in light pipes were studied on models. Computer fluid dynamic simulations aimed at the light pipe thermal profiles were analyzed [27][28][29][30]. The simulations and experimental studies were carried out for integrated daylight-ventilation pipes [31][32][33].…”
Section: Thermal Evaluations Of Light Pipesmentioning
confidence: 99%
“…Emissivity of mirrored surfaces of the light pipe prototype is 0.05 [43]. The thermal monitoring was compared to infrared thermography monitoring for heat transfer models [44] and the previous studies of computer simulations of light pipes thermal profiles [27,28].…”
Section: Infrared Thermographymentioning
confidence: 99%
“…Light transmission efficiency of daylight guidance systems: An assessment approach based on simulations and measurements in a sun/sky simulator [21] Characterization of the photometric performance of tubular light guidance systems in terms of light Light Pipes Performance Prediction: inter model and experimental confrontation on vertical circular light-guides [22] Modeling and experimental analysis of vertical solar tubes Study of light-pipes for the use of sunlight in road tunnels: From a scale model to real tunnels [23] Evaluation of the application of light tubes in tunnel lighting Thermal analysis of light pipes for insulated flat roofs [24] Thermal analysis of solar tubes used in roofs Innovative daylighting systems challenges: A critical study [25] Analysis of existing natural light utilization technologies…”
Section: Title Informationmentioning
confidence: 99%