2015
DOI: 10.1016/j.jobe.2015.01.001
|View full text |Cite
|
Sign up to set email alerts
|

Thermal analysis by DSC of Phase Change Materials, study of the damage effect

Abstract: is an open access repository that collects the work of Arts et Métiers ParisTech researchers and makes it freely available over the web where possible. a b s t r a c tThis paper deals with an experimental study of Phase Change Materials (PCMs) by DSC and focuses particularly on the influence of PCMs damage on their thermodynamic properties. First, different series of tests were performed on non-damaged PCMs (reference) using different masses and heating rates in order to optimize the choice of the experimenta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
30
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 56 publications
(31 citation statements)
references
References 19 publications
1
30
0
Order By: Relevance
“…In most studies, paraffin as the PCM core material is encapsulated in a polymeric shell. Most microencapsulated PCMs used in concrete have either a polymethyl methacrylate (PMMA) [ 59 , 60 , 61 , 62 , 63 , 64 , 65 ] or melamine formaldehyde (MF) shell [ 63 , 66 , 67 , 68 , 69 , 70 ]. In one study, urea formaldehyde was used as a shell material [ 71 ].…”
Section: Phase Change Materials In Concrete Technologymentioning
confidence: 99%
“…In most studies, paraffin as the PCM core material is encapsulated in a polymeric shell. Most microencapsulated PCMs used in concrete have either a polymethyl methacrylate (PMMA) [ 59 , 60 , 61 , 62 , 63 , 64 , 65 ] or melamine formaldehyde (MF) shell [ 63 , 66 , 67 , 68 , 69 , 70 ]. In one study, urea formaldehyde was used as a shell material [ 71 ].…”
Section: Phase Change Materials In Concrete Technologymentioning
confidence: 99%
“…Differential scanning calorimetry (DSC) is an analytical method for measuring the energy difference between a sample and a reference with temperature at a programmed temperature. erefore, the DSC system is the most commonly used approach for the study on the thermal properties of the PCMs such as the melting and freezing temperatures, the specific heat, and the latent heat [39]. According to the measuring principle, it can be divided into heat-flux DSC and power compensation DSC.…”
Section: Thermal Properties Of Pcms With Dscmentioning
confidence: 99%
“…Drissi et al carried out the experimental characterization using differential scanning calorimetry (DSC) to study the damage in the microencapsulated PCM (powder Micronal ® DS 5038X from BASF encapsulated in polymethyl methacrylate shell) and reported that a damaged PCM can lose 28% of latent heat compared to non-damaged PCM [219]. Stearic acid (SA) is used as a PCM and its composite, with titanium dioxide (TiO 2 ), is prepared [76].…”
Section: Experimental Studiesmentioning
confidence: 99%