Order By: Relevance
“…This method is based on high affinity for phospholipids, with low selectivity toward a wide range of basic, neutral, and acidic compounds. 12) We systematically compared the simple protein precipitation procedure to the new sample preparation platform and observed significant improvement in the bioanalysis. Because omeprazole is unstable in acidic solution, we employed acetonitrile for extraction in the Ostro sample preparation procedure instead of acidified acetonitrile, which is recommended to use in the standard protocol.…”
Section: Lc-ms/ms Methods Developmentmentioning
confidence: 99%
“…This method is based on high affinity for phospholipids, with low selectivity toward a wide range of basic, neutral, and acidic compounds. 12) We systematically compared the simple protein precipitation procedure to the new sample preparation platform and observed significant improvement in the bioanalysis. Because omeprazole is unstable in acidic solution, we employed acetonitrile for extraction in the Ostro sample preparation procedure instead of acidified acetonitrile, which is recommended to use in the standard protocol.…”
Section: Lc-ms/ms Methods Developmentmentioning
confidence: 99%
“…The analytical specificity of MS-based immunosuppressant assays is also superior to that of existing immunoassays, which can overestimate the concentration of these medications because of the variable cross-reactivity with immunosuppressant metabolites (32)(33)(34). Lastly, there is now one FDA-approved MS tacrolimus assay (WatersMassTrak®) and several commercially available MS kits with IVD (in vitro diagnostic)-CE certification for the measurement of immunosuppressants (ChromsystemsMassTox®, Recipe-ClinMass®, and Waters-MassTrak®), which make MS-based assays more attractive for smaller laboratories with less expertise (35 ).…”
Section: Advantages Of Msmentioning
confidence: 99%
“…It is recent developments in LC-MS technology that has laid the ground for the successful use of mass spectrometry methods in clinical laboratories (18,19). The development of chromatography using sub 2 µm particles has given increased resolution power and shortened analysis times (20).…”
Section: Mass Spectrometrymentioning
confidence: 99%