Theoretical, Numerical, and Experimental Study of the Time of Flight Flowmeter

Abstract: Time-of-flight flowmeters offer advantages over other flowmeter types since these are less sensitive to the physical properties of the fluid. However, calibration of the flowmeter for a particular working fluid is still required. A flowmeter that does not require re-calibration with different fluids is desirable in many applications. This paper investigates the performance of a device that measures the time of flight of a heat pulse in a gas stream to determine the flow rate in a pipe. A fusion of the theoreti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 15 publications
0
4
0
Order By: Relevance
“…If the flowmeter has no influence on the flow state of water in the pipeline and has no head loss, such as electromagnetic flowmeter and ultrasonic flowmeter, the flowmeter can be equivalently regarded as a part of pipeline and then simulated in the software. If the flowmeter has head loss, such as differential pressure flowmeter and thermal time of flight flow meter [42], the flowmeter cannot be simulated in the software.…”
Section: Data Availability Statementmentioning
confidence: 99%
“…If the flowmeter has no influence on the flow state of water in the pipeline and has no head loss, such as electromagnetic flowmeter and ultrasonic flowmeter, the flowmeter can be equivalently regarded as a part of pipeline and then simulated in the software. If the flowmeter has head loss, such as differential pressure flowmeter and thermal time of flight flow meter [42], the flowmeter cannot be simulated in the software.…”
Section: Data Availability Statementmentioning
confidence: 99%
“…In the turbine flowmeters, the frequency generated by the rotation of a rotor is directly proportional to the flowrate. 2 These steadily calibrated devices can be applied to measure unsteady flowrates, 3 but only pulsating 4,5 or intermittent 6 ones with a lower frequency than 1 kHz can be considered.…”
Section: Introductionmentioning
confidence: 99%
“…The frequency caused by the impeller rotation, which is directly correlated with the flowrate, is measured in turbine flowmeters [2]. These devices, calibrated in steady state conditions, can be used to monitor unsteady flow rates [3], although only pulsing [4,5], or intermittent [6] flows with frequencies less than 1 kHz can be considered.…”
Section: Introductionmentioning