2015
DOI: 10.1016/j.ijrefrig.2015.05.020
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical model of the operation parameters regulated by the MIMO and SISO system in a cooling chamber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 2 publications
0
4
0
Order By: Relevance
“…The difference is then used to adjust some input to the process in order to bring the process measured value back to its desired set point [6]. PID controller makes rapid and precise control possible [7][8][9][10][11]. This is also true in reality, provided that the system is correctly defined, taking disturbances into consideration accurately.…”
Section: Introductionmentioning
confidence: 99%
“…The difference is then used to adjust some input to the process in order to bring the process measured value back to its desired set point [6]. PID controller makes rapid and precise control possible [7][8][9][10][11]. This is also true in reality, provided that the system is correctly defined, taking disturbances into consideration accurately.…”
Section: Introductionmentioning
confidence: 99%
“…Reduction in the energy consumption of refrigeration systems is crucial topic of the industry. The energy consumption is significant influenced by the type of the compressor, the control techniques of compressor, expansion valve and refrigerant [1][2][3]. In the study conducted by Ekren [4], performance of the variable speed operation and constant speed operation during ON and on/off mode of the same DC compressor has been compared.…”
Section: Introductionmentioning
confidence: 99%
“…Likewise, designing an appropriate controller becomes a big challenge [5,6]. HVAC system is a multiple-Input and multiple-output (MIMO) system, sometimes with coupled parameters [7]. Moreover, it is a complex nonlinear system, which makes deriving the exact mathematical model a challenging task [3].…”
mentioning
confidence: 99%
“…The humidity load generation in the air-conditioned room is M. According to the authors of [3], Equations (1)-(5) and (7), which are all first order differential equations, could form the dynamic model of the DX A/C system. On the basis of the work done by Qi [22], Equations (1)- (7) are used as a dynamic mathematical model of the experimental DX A/C system and have been experimentally validated.…”