2017
DOI: 10.1080/01457632.2017.1312899
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical Investigation on Thermal Performance of New Structure Closed Wet Cooling Tower

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…Evaporative coolers have the advantages of saving water [1], saving energy [2], and having a compact structure, and have been widely used in industrial cooling [2][3][4], heat pump systems [5], refrigeration systems [6], data centers [7], and other fields. To design evaporative coolers reasonably, extensive research has been carried out on the heat and mass transfer of evaporative coolers.…”
Section: Introductionmentioning
confidence: 99%
“…Evaporative coolers have the advantages of saving water [1], saving energy [2], and having a compact structure, and have been widely used in industrial cooling [2][3][4], heat pump systems [5], refrigeration systems [6], data centers [7], and other fields. To design evaporative coolers reasonably, extensive research has been carried out on the heat and mass transfer of evaporative coolers.…”
Section: Introductionmentioning
confidence: 99%
“…Zhou et al investigated the thermal performance of a closed wet cooling tower (CWCT) with and without packing. The result shows that the outlet temperature of CWCT with packing lowers between 0.6°C and 1.5°C and the cooling efficiency of CWCT with packing is higher than that without packing between 6.0% and 14.8%.…”
Section: Introductionmentioning
confidence: 99%
“…The simulation result demonstrated that the thermal performance of the new cooling tower was always higher than that of the usual cooling tower at the wind velocity greater than 3 m/s. Zhou et al 25 investigated the thermal performance of a closed wet cooling tower (CWCT) with and without packing. The result shows that the outlet temperature of CWCT with packing lowers between 0.6°C and 1.5°C and the cooling efficiency of CWCT with packing is higher than that without packing between 6.0% and 14.8%.…”
Section: Introductionmentioning
confidence: 99%
“…Zhou et al investigated the thermal performance of closed wet cooling tower (CWCT) with and without packing. The result shows that the effectiveness of CWCT with packing is more by 6 to 14.8% as compared to without packing.…”
Section: Introductionmentioning