2017
DOI: 10.1016/j.jngse.2017.03.034
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical investigation of the compression limits of sealing structures in complex load transferring between subsea connector components

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
28
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 31 publications
(30 citation statements)
references
References 13 publications
0
28
0
Order By: Relevance
“…Since there are so many labour intensive steps workers often take shortcuts to which have consequences later in the buildings life. For example pushing the backing rod too far in may result in adhesion failure as the layer of caulking/sealing must not be too thick as not to be able to accommodate for the tolerances required when the building/panels move be it due to thermal expansion or for dynamic reasons [9]. The adhesion fails and separation occurs as the caulking/sealant is not in the narrow hourglass figure and hence the increase pulling force acting against the adhesion.…”
Section: Conventional Solutionmentioning
confidence: 99%
“…Since there are so many labour intensive steps workers often take shortcuts to which have consequences later in the buildings life. For example pushing the backing rod too far in may result in adhesion failure as the layer of caulking/sealing must not be too thick as not to be able to accommodate for the tolerances required when the building/panels move be it due to thermal expansion or for dynamic reasons [9]. The adhesion fails and separation occurs as the caulking/sealant is not in the narrow hourglass figure and hence the increase pulling force acting against the adhesion.…”
Section: Conventional Solutionmentioning
confidence: 99%
“…Using sealant as the primary means of weatherproofing without further protection such as a drained joint is fundamentally not a rigorous solution especially considering that the joint can only be inspected from the outside. The time where the use of sealant that can be best relied upon in this manner is when used between glass to glass joint's where both sides can be easily inspected and the design requires openness [11].…”
Section: Conventional Solutionmentioning
confidence: 99%
“…Poor workmanship along with sealant distress are amongst the leading reasons for why a building will leak [11]. Therefore there is a need to develop new seals which do not rely as heavily on workmanship and are able to be completed offsite are required for prefabricated forms of construction.…”
Section: Conventional Solutionmentioning
confidence: 99%
“…Since there are so many labour intensive steps workers often take shortcuts to which have consequences later in the buildings life. For example pushing the backing rod too far in may result in adhesion failure as the layer of caulking/sealing must not be too thick as not to be able to accommodate for the tolerances required when the building/panels move be it due to thermal expansion or for dynamic reasons [7]. The adhesion fails and separation occurs as the caulking/sealant is not in the narrow hourglass figure and hence the increase pulling force acting against the adhesion.…”
Section: Conventional Solutionmentioning
confidence: 99%