2014
DOI: 10.5755/j01.mech.20.1.6590
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical aspects of the calibration of geodetic angle measurement instrumentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
5
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 6 publications
0
5
0
1
Order By: Relevance
“…Fuel consumption (l or l h -1 ) was measured by AIC-4004 VERITAS (AIC SYSTEMS AG) fuel flow meter. Calibration of all devices was performed according to standard procedures (Barzdžiukas, Augutis, & Žilinskas, 2012;Bručas, Šiaudinytė, Rybokas, & Grattan, 2014;Naranjo, Sandu, Taheri, & Taheri, 2014). Error did not exceed ±2%.…”
Section: Equipment Site and Layoutmentioning
confidence: 99%
“…Fuel consumption (l or l h -1 ) was measured by AIC-4004 VERITAS (AIC SYSTEMS AG) fuel flow meter. Calibration of all devices was performed according to standard procedures (Barzdžiukas, Augutis, & Žilinskas, 2012;Bručas, Šiaudinytė, Rybokas, & Grattan, 2014;Naranjo, Sandu, Taheri, & Taheri, 2014). Error did not exceed ±2%.…”
Section: Equipment Site and Layoutmentioning
confidence: 99%
“…The method for calibration of vertical angle measuring systems of geodetic instruments was developed at Institute of Geodesy of Vilnius Gediminas Technical University. This method proposes an arrangement to create the reference angle suitable for vertical angle calibration purposes in the laboratory environment [3,4].…”
Section: The Principle and Instrumentationmentioning
confidence: 99%
“…A range of vertical angle sensors and instruments, including electronic levels, inclinometers, theodolites, and total stations, are employed for this purpose [1][2][3][4][5][6][7][8][9]. Proper calibration of these sensors and instruments is crucial to ensure high reliability and improve measurement accuracy [10][11][12][13][14]. Consequently, several National Measurement Institutes have developed standard angle comparators and offer calibration services for vertical angle sensors and instruments.…”
Section: Introductionmentioning
confidence: 99%
“…A comparison of technical specifications of various angle measuring methods applicable to geodetic angle measurement instruments was conducted. Horizontal angles of a total station were evaluated using a precision rotary table, while vertical angles were assessed using a trigonometric method [12]. Another method utilized an index table and an autocollimator to calibrate the vertical angle of a total station [13].…”
Section: Introductionmentioning
confidence: 99%