2022
DOI: 10.1002/ep.14041
|View full text |Cite
|
Sign up to set email alerts
|

Theoretical analysis and experimental research on R1234yf as alternative to R134a in a heat pump system

Abstract: With the growing awareness of dual threats of global warming potential (GWP) and ozone depletion potential (ODP), the theoretical analysis and experimental testing of R1234yf refrigerant as alternative to R134a in a heat pump were analyzed. The results show that when the discharge pressure decreases from 1.6 MPa to 0.9 MPa, the heating COP h of R134a and R1234yf heat pumps decreases by 26.97% and 28.78%, respectively. When the evaporation temperature increases from À10 to 10 C, the heating COP h of R134a and R… Show more