2011
DOI: 10.1002/jps.22312
|View full text |Cite
|
Sign up to set email alerts
|

Theophylline-Loaded Compritol Microspheres Prepared by Ultrasound-Assisted Atomization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
9
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 31 publications
5
9
0
Order By: Relevance
“…In the diffractogram of the physical mixture, the characteristic peaks of Compritol ® were present at 21.27° 2θ and at 23.35° 2θ, confirming its crystallinity and presence in β' form, as previously suggested by DSC results. 43 The crystalline peaks of SL at 16.01, 16.67, and 17.29° 2θ were evident but with lower intensities in the physical mixture, confirming the presence of SL in crystalline form. On the contrary, the diffractogram of SL-NLC formulation showed a deformed peak for SL, signifying that the drug lost its crystallinity and was transformed to an amorphous state or molecular dispersion within the nanocarriers.…”
Section: Dsc Analysismentioning
confidence: 80%
“…In the diffractogram of the physical mixture, the characteristic peaks of Compritol ® were present at 21.27° 2θ and at 23.35° 2θ, confirming its crystallinity and presence in β' form, as previously suggested by DSC results. 43 The crystalline peaks of SL at 16.01, 16.67, and 17.29° 2θ were evident but with lower intensities in the physical mixture, confirming the presence of SL in crystalline form. On the contrary, the diffractogram of SL-NLC formulation showed a deformed peak for SL, signifying that the drug lost its crystallinity and was transformed to an amorphous state or molecular dispersion within the nanocarriers.…”
Section: Dsc Analysismentioning
confidence: 80%
“…Drug content (%w/w ± SD) Thickness (mm ± SD) Amount of mucin adsorbed per patch total surface area (mcg/cm 2 A C18 column Inertsil Ò ODS-3, 5 lm, 150 Â 4.6 mm (Japan) was used for the chromatographic separation. The analysis was performed at the multiple reaction monitoring mode (MRM) [20].…”
Section: Formulamentioning
confidence: 99%
“…The molten mass was rapidly cooled over an ice bath and allowed to solidify. The solidified mass was pulverized in a mortar then sieved through 0.5 lm sieve [2,4].…”
Section: Preparation Of Tiz Compritol-based Hot-meltsmentioning
confidence: 99%
See 1 more Smart Citation
“…The methods commonly used in microsphere preparation include emulsion method 8 , phase separation method 9 , spray drying method 10 , ultrasonic atomization method 11 , electrospray method 12 , and microfluidic method 13 . Among the above-mentioned methods, spray drying method is most widely used in manufacture scale and the emulsion methods are commonly accepted in laboratory level.…”
mentioning
confidence: 99%