1990
DOI: 10.1002/jbm.820241102
|View full text |Cite
|
Sign up to set email alerts
|

The wear behavior of ion‐implanted Ti‐6Al‐4V against UHMW polyethylene

Abstract: Nitrogen-ion-implanted Ti-6A1-4V against UHMW polyethylene was tested on a joint simulator to evaluate the wear behavior under different conditions. It was concluded that the polymer wear rate was not affected by ion implantation. The metallic wear, on the other hand, was substantially reduced by this treatment. It was also found that ion implantation resulted in good protection of the metal surface against third-body wear by PMMA, while the introduction of C.P. titanium particles in the joint initiated tremen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0
1

Year Published

1996
1996
2008
2008

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 98 publications
(28 citation statements)
references
References 12 publications
0
27
0
1
Order By: Relevance
“…The problem has been recognized for a long time, but only in the last several years has it received significant attention from manufacturers, surgeons and researchers. In order to enhance the tribological properties as well as wear resistance of the metallic components in the artificial joints, various procedures have been suggested including ion implantation, plasma coating, and plasmagrafting [157][158][159]. Ion implantation has been the most common treatment method [106,158,160].…”
Section: Plasma-surface Modification Of Hard Tissue Replacementsmentioning
confidence: 99%
See 1 more Smart Citation
“…The problem has been recognized for a long time, but only in the last several years has it received significant attention from manufacturers, surgeons and researchers. In order to enhance the tribological properties as well as wear resistance of the metallic components in the artificial joints, various procedures have been suggested including ion implantation, plasma coating, and plasmagrafting [157][158][159]. Ion implantation has been the most common treatment method [106,158,160].…”
Section: Plasma-surface Modification Of Hard Tissue Replacementsmentioning
confidence: 99%
“…Ion implantation has been the most common treatment method [106,158,160]. The improvement in the sliding wear resistance of the implanted materials can turn out to be either little or substantial, but that in wear resistance is more consistent [157].…”
Section: Plasma-surface Modification Of Hard Tissue Replacementsmentioning
confidence: 99%
“…Other protocols have placed third body particles directly in the articulating surface (Davidson et al, 1994;McKellop et al, 1981;McKellop and Rostlund, 1990;McNie et al, 2000), or have indirectly simulated third body effects using abrasion-tumbling, emery abrasion, or discrete scratching of femoral heads (Affatato et al, 2005;Barbour et al, 2000;Endo et al, 2001;McKellop et al, 1999;Wang et al, 1998); many of these studies also demonstrated increased polyethylene wear resulting from third body effects.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the craters may accept debris of different origin that otherwise might have played a role as a third body between the two surfaces. This type of femoral head probably deserves more attention [6,7] and should be evaluated in vivo long term.…”
Section: Hip-simulator Analysismentioning
confidence: 99%