Research in Building Physics 2020
DOI: 10.1201/9781003078852-125
|View full text |Cite
|
Sign up to set email alerts
|

The vibration reduction index Kij: laboratory measurements versus predictions EN 12354-1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
1
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 4 publications
0
1
0
3
Order By: Relevance
“…To examine the effect of the concrete core fill on the floorfloor flanking path, the vibration reduction index of the path in question was examined with and without the core fill using the finite element method (FEM). FEM can predict vibration transmission between concrete structures with sufficient accuracy [2], and it has been previously used for investigating the vibration reduction index of building junctions [2][3][4][5][6]. Additionally, FEM allows the complex geometry of the hollow core slabs and the core fill to be taken into account accurately.…”
Section: Introductionmentioning
confidence: 99%
“…To examine the effect of the concrete core fill on the floorfloor flanking path, the vibration reduction index of the path in question was examined with and without the core fill using the finite element method (FEM). FEM can predict vibration transmission between concrete structures with sufficient accuracy [2], and it has been previously used for investigating the vibration reduction index of building junctions [2][3][4][5][6]. Additionally, FEM allows the complex geometry of the hollow core slabs and the core fill to be taken into account accurately.…”
Section: Introductionmentioning
confidence: 99%
“…Resilient joints between building constructions reduce vibration transmission from one element to another [4]. Because of that, it is a frequent impression among building engineers that resilient joints in any position close to the joint positively affect the sound insulation between two rooms.…”
Section: Introductionmentioning
confidence: 99%
“… La ejecución influencia los resultados de aislamiento acústico y posiblemente también los resultados del índice K ij . Por ejemplo, las fisuras en las uniones entre elementos constructivos o en las propias particiones, afectan a los índices K ij [97] y no están recogidas en el modelo de cálculo.…”
Section: Dificultades En La Aplicación De La Une-en 12354-1 En Proyec...unclassified
“…Figura 12.2, los valores calculados son menores que los valores resultantes de los ensayos. Esto también ha sido descrito por otros autores como Crispin, et al [78,97]. Se observa un incremento del índice K ij a partir de 400 Hz de 4,5 dB/octava en este caso.…”
Section: Grupo1 Análisis De Las Uniones Rígidas Agrupadas En T Y Cruzunclassified
See 1 more Smart Citation