The Vertical Projection of the Sum of the Ground Reactive Forces of a Standing Patient Is Not the Same as the C7 Plumb Line

Abstract: We speculate that this information will be very helpful in evaluating symptomatic spinal disease in the context of the overall alignment of the spine and pelvis.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

6
108
2
10

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
3

Relationship

2
6

Authors

Journals

citations
Cited by 208 publications
(134 citation statements)
references
References 24 publications
(30 reference statements)
6
108
2
10
Order By: Relevance
“…Angular parameter is represented by the spino-sacral angle (SSA) and the ratio corresponds to the C7 plumbline/sacro-femoral distance ratio (C7/SFD). These two parameters have already been reported and validated [1,21].…”
Section: Global Balance Evaluationmentioning
confidence: 79%
“…Angular parameter is represented by the spino-sacral angle (SSA) and the ratio corresponds to the C7 plumbline/sacro-femoral distance ratio (C7/SFD). These two parameters have already been reported and validated [1,21].…”
Section: Global Balance Evaluationmentioning
confidence: 79%
“…Roussouly [7] defined a mathematical formula associating SSA angle and sacral slope: SSA = 0.96SS ? 97°.…”
Section: Discussionmentioning
confidence: 99%
“…2); this is an intrinsic parameter [7]. In a balanced spine, SSA is extremely strongly correlated with the sacral slope angle (R = 0.91, P \ 0.001) according to Roussouly [7] and this could be an important parameter in analysis of the study population.…”
Section: Sagittal Balance Parametersmentioning
confidence: 91%
“…The distance from the radiographic source to the film was maintained at 230 cm for all exposures and the edges of the radiographic film were square in respect to the horizontal and vertical axes. The films were digitized with a commercially available optical scanner (VIDARVXR-8, Vidar Systems Inc., USA) [5]. In order to reduce any inaccuracy caused by head motion, patients were asked to stand in comfortable position and gaze horizontally.…”
Section: Methodsmentioning
confidence: 99%
“…2b based on Cobb's measurement. Additional radiological parameters included pelvic incidence (PI) [6], sacral slope (SS) [6], pelvic tilt (PT) [6], spinal sacral angle (SSA) [5], ratio of hip to C7/hip to sacrum [5] (Fig. 3), Roussouly sagittal classifications [7], Lenke Curve Type, Lenke Lumbar Modifier [8].…”
Section: Methodsmentioning
confidence: 99%