2010
DOI: 10.1016/j.jct.2010.01.012
|View full text |Cite
|
Sign up to set email alerts
|

The vaporization of NH4NO3

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
19
0

Year Published

2012
2012
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(21 citation statements)
references
References 22 publications
(35 reference statements)
2
19
0
Order By: Relevance
“…The measured evaporation of AN was reproduced using C * and H VAP of 76 µg m −3 (corresponding to 2.6 × 10 −3 Pa) and 152 kJ mol −1 , respectively. The obtained H VAP is 1.5 times higher than reported previously (Brandner et al, 1962;Hildenbrand et al, 2010a, b;Salo et al, 2011), and the saturation vapor concentration is of the same magnitude as in previous studies (Brandner et al, 1962;Chien et al, 2010). For AS, C * and H VAP of 2 × 10 −3 µg m −3 and H VAP of 94 kJ mol −1 reproduced the measurements best.…”
Section: Kinetic Evaporation Modelsupporting
confidence: 73%
See 2 more Smart Citations
“…The measured evaporation of AN was reproduced using C * and H VAP of 76 µg m −3 (corresponding to 2.6 × 10 −3 Pa) and 152 kJ mol −1 , respectively. The obtained H VAP is 1.5 times higher than reported previously (Brandner et al, 1962;Hildenbrand et al, 2010a, b;Salo et al, 2011), and the saturation vapor concentration is of the same magnitude as in previous studies (Brandner et al, 1962;Chien et al, 2010). For AS, C * and H VAP of 2 × 10 −3 µg m −3 and H VAP of 94 kJ mol −1 reproduced the measurements best.…”
Section: Kinetic Evaporation Modelsupporting
confidence: 73%
“…A high-resolution aerosol mass spectrometer (HR-AMS, Aerodyne Research Inc., Billerica, USA) was used to determine the chemical composition of aerosol particles during the experimental period. Detailed description of the instrument, measurement and data processing can be found in other publications (DeCarlo et al, 2006;Canagaratna et al, 2007). A Sunset semi-continuous OC / EC analyzer was deployed to determine the mass concentrations of organic carbon (OC) and elemental carbon (EC) concentrations in aerosols using a thermal-optical protocol (Bauer et al, 2009).…”
Section: Particle Chemical Compositionmentioning
confidence: 99%
See 1 more Smart Citation
“…The exact reasoning behind the observed isotope fractionation effects, however, is beyond the scope of the current manuscript. In principle, 15 N fractionation for the conversion of the ammonia nitrogen atom into the β position of the N 2 O molecule might occur during the initial reaction step, NH 4 NO 3 dissociation into ammonia (NH 3 ) and nitric acid (HNO 3 ), as studied by Urey et al ., or the oxidation of NH 3 by a nitronium ion (NO 2 + ), which yields N 2 O and H 2 O. NO 2 + is generated in an intermediate reaction step by protonation of HNO 3 to H 2 NO 3 + and H 2 O cleavage …”
Section: Resultsmentioning
confidence: 99%
“…However, in addition to differences in single-particle vaporization event peak area, also differences in peak width and shape can be seen for the three ions. This is likely associated with the thermal decomposition processes occurring during the particle vaporization event (Chien et al, 2010;Ellis and Murray, 1953;Rosser and Wise, 1956):…”
Section: Single-particle Vaporization Eventsmentioning
confidence: 99%