The Value of Rotational Venography Versus Anterior–Posterior Venography in 100 Consecutive IVC Filter Retrievals

Abstract: Rotational venograms allow for more accurate detection of tip-embedded IVC filters compared to AP views alone. As this determines the approach taken, rotational venograms are helpful if obtained prior to IVC filter retrieval.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 22 publications
(42 reference statements)
0
5
0
Order By: Relevance
“…Briefly, spot magnification radiographs were obtained of all filters to evaluate for fracture (Fig 3a). After obtaining right internal jugular vein access for Günther Tulip and Option removals or femoral vein access for OptEase retrievals, rotational venography was performed using a flush catheter and half-strength contrast material (iopamidol [ISOVUE-M 300; Bracco Diagnostics, Monroe Township, New Jersey]) with an injection rate of 15 mL/s for 6 seconds and a 2 second x-ray delay to evaluate for tip embedding (Fig 3b) (21). A snare was used for the first eight tip-centered filters (Fig 3c), whereas 3-mm endobronchial forceps (4162; LYMOL Medical) was used immediately with tip-adherent and tip-embedded filters.…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, spot magnification radiographs were obtained of all filters to evaluate for fracture (Fig 3a). After obtaining right internal jugular vein access for Günther Tulip and Option removals or femoral vein access for OptEase retrievals, rotational venography was performed using a flush catheter and half-strength contrast material (iopamidol [ISOVUE-M 300; Bracco Diagnostics, Monroe Township, New Jersey]) with an injection rate of 15 mL/s for 6 seconds and a 2 second x-ray delay to evaluate for tip embedding (Fig 3b) (21). A snare was used for the first eight tip-centered filters (Fig 3c), whereas 3-mm endobronchial forceps (4162; LYMOL Medical) was used immediately with tip-adherent and tip-embedded filters.…”
Section: Methodsmentioning
confidence: 99%
“…According to one study, the location and position of IVC filter limb penetration could be determined using CT scans performed prior to retrieval procedures; 89% of those filters were subsequently retrieved successfully [ 10 ]. By accurately identifying 58 out of 59 tip-embedded filters, rotational venography demonstrated its efficacy in reducing the complexities associated with retrieval methods that are complex in nature [ 14 , 27 ].…”
Section: Reviewmentioning
confidence: 99%
“…Filter removal was performed with a jugular (n = 62) or femoral (n = 1, OptEase) approach. Initially, rotational cavography was performed (16,17) to determine the relationship of the filter and fragment(s) to the wall and to the filter itself. Following careful evaluation, a determination was made to remove either the fragment(s) or the filter first.…”