The use of Vacutainer tubes for collection of soil samples for helium analysis

Abstract: Measurements of the helium concentration of soil samples collected and stored in Vacutainer-brand evacuated glass tubes show that Vacutainers are reliable containers for soil collection.Within the limits of reproducibility, helium content of soils appears to be independent of variations in soil temperature, barometric pressure, and quantity of soil moisture present in the sample.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
4

Year Published

1985
1985
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(17 citation statements)
references
References 3 publications
0
13
0
4
Order By: Relevance
“…La extracción del gas del ambiente superficial del suelo se realizó mediante la inserción de una sonda metálica a 30-40 cm de profundidad y el uso de una jeringuilla hipodérmica de 20 cc. Las muestras de gas extraídas del suelo se almacenaron en tubos de vidrio evacuados de 10 cc de capacidad (Hinkle & Kilburn, 1979). El análisis químico de las muestras se realizó mediante el empleo de un sistema de microcromatografía de gases, modelo VARIAN 2002P.…”
Section: Metodologíaunclassified
“…La extracción del gas del ambiente superficial del suelo se realizó mediante la inserción de una sonda metálica a 30-40 cm de profundidad y el uso de una jeringuilla hipodérmica de 20 cc. Las muestras de gas extraídas del suelo se almacenaron en tubos de vidrio evacuados de 10 cc de capacidad (Hinkle & Kilburn, 1979). El análisis químico de las muestras se realizó mediante el empleo de un sistema de microcromatografía de gases, modelo VARIAN 2002P.…”
Section: Metodologíaunclassified
“…Soil gases were sampled at each sampling site together with ground temperature measurements at a depth of 30-50 cm using a metallic soil probe and 30 cc hypodermic syringes. The gas samples were introduced in 10 cc vacutainers (HINKLE and KILBURN, 1979) filled with deionised water. Later the water was displaced until the vacutainer was filled with the gas sample to avoid air contamination.…”
Section: Procedures and Methodsmentioning
confidence: 99%
“…La toma de muestra de gas se realizó extrayendo 30 cm 3 de gas con una jeringuilla hipodérmica y transfiriendo una alícuota de este a un vial sellado de 10 cm 3 . Para la toma de muestra, se utilizó una variante del método descrito por Hinkle & Kilburn (1979), consistente en introducir la muestra de gas en un vial sellado y llenado previamente de agua, de forma que el gas desplaza el agua contenida en el vial. Con este método evitamos que los gases más ligeros se escapen a través de las paredes del tapón del vial debido a la cámara de agua que queda en el interior después de introducir la muestra.…”
Section: Metodologíaunclassified