2008
DOI: 10.1007/s00417-008-0828-1
|View full text |Cite
|
Sign up to set email alerts
|

The use of semi-automated kinetic perimetry (SKP) to monitor advanced glaucomatous visual field loss

Abstract: The comparability between SKP and ASP is satisfactory and within the range of the test-retest reliability of ASP. SKP shows slightly better test-retest reliability than ASP. The majority of patients with advanced glaucomatous visual field loss prefer SKP instead of ASP. SKP is a valuable alternative to ASP in monitoring advanced glaucomatous visual field loss.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
16
0
5

Year Published

2010
2010
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 23 publications
(22 citation statements)
references
References 24 publications
1
16
0
5
Order By: Relevance
“…3,15,26 SKP using the Octopus is becoming the test of choice by many clinical departments due to a more standardised method compared with the Goldmann perimeter 19 and good test-retest reliability. 18 Despite this, there are no normative published data of children's VF area, expected RTs, and blind spot size as a function of age. Also lacking is information regarding feasibility of testing and effect of stimulus velocity.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…3,15,26 SKP using the Octopus is becoming the test of choice by many clinical departments due to a more standardised method compared with the Goldmann perimeter 19 and good test-retest reliability. 18 Despite this, there are no normative published data of children's VF area, expected RTs, and blind spot size as a function of age. Also lacking is information regarding feasibility of testing and effect of stimulus velocity.…”
Section: Introductionmentioning
confidence: 99%
“…A range is found in the literature. In normative VFs, Vonthein et al 13 18,19 Static perimetry strategies use false-positive, falsenegative, and fixation loss indices to provide measures of reliability. [20][21][22] For static perimetry, Artes et al 21 considered RTs less than 180 ms and greater than 2000 ms to represent false-positive and falsenegative responses, respectively, and these criteria have also been employed in SKP.…”
Section: Introductionmentioning
confidence: 99%
“…Nos casos de dano glaucomatoso avançado, as alterações morfológicas no nervo óptico são difíceis de avaliar pois estão no limite para medida e observação de sua progressão. Nestes casos, a perimetria assume um papel importante considerando-se que uma discreta alteração morfológica resulta em uma visível alteração campimétrica (8) .…”
Section: Discussionunclassified
“…No entanto, estes estudos enfatizaram casos iniciais de perda glaucomatosa do campo visual. Em casos de perda avança-da de campo visual o uso da perimetria limiar estática padrão, que testa a sensibilidade bem próxima ao limiar, pode ser ineficiente, demorada e cansativa ao paciente (8) .…”
Section: Discussionunclassified
See 1 more Smart Citation