The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery

Abstract: Standard silver-based films are usually too sensitive to be used as direct indicators of dose in dynamic radiosurgery because of optical saturation. This paper describes the use of a new radiochromic film to measure 6-MV radiosurgery doses and dose distributions in a head phantom. Dose calibration of the radiochromic film was performed in the range of 2.3-50.2 Gy using light of 632- and 530-nm wavelengths. Radiosurgery dose distributions were measured using the radiochromic film in a head phantom undergoing th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0
1

Year Published

2003
2003
2022
2022

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(36 citation statements)
references
References 0 publications
0
35
0
1
Order By: Relevance
“…The Lucy phantom ( 14 , 16 ) from Standard Imaging (Middleton, WI, USA) was used to assess the end‐to‐end accuracy of the SAlinac system. The Lucy phantom was loaded with 2.5 inch by 2.5 inch pieces of GAFCHROMIC film and CT scanned in the Radionics Brown–Robert–Wells (BRW) frame and localizer rods, as is done for patients.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Lucy phantom ( 14 , 16 ) from Standard Imaging (Middleton, WI, USA) was used to assess the end‐to‐end accuracy of the SAlinac system. The Lucy phantom was loaded with 2.5 inch by 2.5 inch pieces of GAFCHROMIC film and CT scanned in the Radionics Brown–Robert–Wells (BRW) frame and localizer rods, as is done for patients.…”
Section: Resultsmentioning
confidence: 99%
“…For convenience, the algorithms could be generalized to process an image from an electronic portal imaging device (EPID) instead of data from the film scanner. ( 12 , 13 ) We began a study with GAFCHROMIC ( 14 ) EBT film (International Specialty Products, Wayne, NJ), but it requires at least 200 to 300 MU to obtain a reasonable image, and the scanned image was not as good as for XV film. For the Winston‐Lutz tests in this study, we exclusively used XV film and 50 MU per shot to first discover the best attainable accuracy with the system.…”
Section: Methodsmentioning
confidence: 99%
“…Even in one study with GAFCHROMIC films, up to ±1mm uncertainty was detected in isocenter positioning. ( 64 ) …”
Section: Methodsmentioning
confidence: 99%
“…Güte der gesamten Kette (des Systems) (Abbildung 2), zum zweiten Messungen von Outputfaktoren [6,15,33] bzw. Profilen [32] und zum dritten die experimentelle Verifizierung von komplizierten dreidimensionalen Dosisverteilungen [5,13,26]. Es ist von entscheidender Bedeutung, inwieweit berechnete bzw.…”
Section: Diskussionunclassified