1990
DOI: 10.1366/0003702904085949
|View full text |Cite
|
Sign up to set email alerts
|

The Use of Poly(Tetrafluoroethylene-Co-Hexafluoropropylene) Tubing as a Waveguide Capillary Cell for Liquid Absorption Spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
10
0

Year Published

1991
1991
2021
2021

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 25 publications
(10 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…As a result, several promising flow injection analysis (FIA) systems including on-line sample pre-treatment and flowthrough detection have been constructed. [13][14][15] In order to increase the sensitivity in such FIA systems, some researchers have employed the liquid core waveguide as an optical cell with a long pathlength, [16][17][18] and others have applied solid-phase spectrophotometry, 19,20 in which the absorbance of analyte species adsorbed and enriched on a solid support placed inside the light path of the flow cell is directly measured.…”
Section: Introductionmentioning
confidence: 99%
“…As a result, several promising flow injection analysis (FIA) systems including on-line sample pre-treatment and flowthrough detection have been constructed. [13][14][15] In order to increase the sensitivity in such FIA systems, some researchers have employed the liquid core waveguide as an optical cell with a long pathlength, [16][17][18] and others have applied solid-phase spectrophotometry, 19,20 in which the absorbance of analyte species adsorbed and enriched on a solid support placed inside the light path of the flow cell is directly measured.…”
Section: Introductionmentioning
confidence: 99%
“…12 Tsunoda et al demonstrated the application of using 45% w/w ethanol for the light-guiding device and applied it for a long path absorption measurement of tryptophan. 13 Teshima et al applied a concentrated NaOH medium as an mLCW in the FEP tube for a long path absorption measurement for the acetone determination in exhaled breath. 14 Recently, the syrup or ethanol was used as cost-effective environmentally friendly mLCW in a GD-FI system employing a butterfly pea flower extract reagent for ammonium determination.…”
Section: Introductionmentioning
confidence: 99%
“…The concern on insufficient sensitivity of optical measurement could be overcome by using the liquid core waveguide (LCW) technique [18][19][20]. In this technique, the cell is made of material of a smaller refractive index than that of the liquid in the cell core, which facilitates total reflection of transmitting light at the liquid core-cell wall interface.…”
mentioning