Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2012
DOI: 10.1071/en12103
|View full text |Cite
|
Sign up to set email alerts
|

The use of permeation liquid membranes for free zinc measurements in aqueous solution

Abstract: Environmental context The free Zn ion concentration in environmental aqueous systems is an important factor in determining Zn deficiency or toxicity to organisms as this species is directly bioavailable. The permeation liquid membrane technique, a tool to measure either free or bioavailable metal concentrations in solution depending on its setup, was evaluated for the first time for Zn speciation in simplified plant nutrient solutions. The technique is low-cost and applicable to a broad range of aqueous sample… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2013
2013
2018
2018

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 32 publications
0
10
0
Order By: Relevance
“…[24] Uptake of intact complexes by plants may also explain why histidine caused a larger deviation than citrate between measured Zn fluxes into plants and predictions based on the relationship between root and PLM Zn fluxes in the EDTA and no ligand treatments (Fig. 5b(i)), whereas it cannot be excluded on the other hand that faster complex dissociation was at least partially responsible also for this difference between histidine and citrate treatments.…”
Section: Discussionmentioning
confidence: 86%
See 3 more Smart Citations
“…[24] Uptake of intact complexes by plants may also explain why histidine caused a larger deviation than citrate between measured Zn fluxes into plants and predictions based on the relationship between root and PLM Zn fluxes in the EDTA and no ligand treatments (Fig. 5b(i)), whereas it cannot be excluded on the other hand that faster complex dissociation was at least partially responsible also for this difference between histidine and citrate treatments.…”
Section: Discussionmentioning
confidence: 86%
“…The DGT available concentration (C DGT ) was calculated according to the DGT research manual. [33] PLM experiment Hollow fibre PLM (HF-PLM) experiments were set up in the same way as described by Gramlich et al [24] using a carrier concentration of 0.05 M lauric acid (LA) and 0.1 M Kryptofix 22DD in the organic membrane (1/1, v/v, toluene/hexylbenzene mixture) and PLM membranes of 31-cm length. After 2-h exposure of the PLM membranes to the treatment solutions (Table 1), the Zn concentrations of the strip solutions were measured using ICP-OES (Vista-MPX, Varian).…”
Section: Dgt Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…Many analytical techniques like ion-exchange methods, [1] the Donnan membrane technique (DMT) [2,3] or permeation liquid membrane (PLM) technique [4] have been developed to determine the free metal ion concentrations in natural samples. These methods agree well with speciation models (Windermere Humic Aqueous Model, WHAM, or Visual Minteq), [5][6][7][8] but require complementary equipment that cannot be moved into the field for on-site measurements.…”
Section: Introductionmentioning
confidence: 99%