THE USE OF NEW INSERTER (R_INSERTER) FOR DELIVERING CuT-380A IUD DURING POSTPARTUM PERIOD PHASE II CLINICAL TRIAL

Abstract: Latar Belakang: IUD adalah salah satu alat kontrasepsi jangka panjang yang efektif, tetapi penggunaan di Indonesia masih rendah. Karena inserter IUD yang biasa di pakai terlalu pendek untuk pemasangan segera pascasalin maka bentuk inserter baru (R_inseter) telah dikembangkan. Tujuan: Untuk mengetahui apakah R_inserter dapat digunakan dengan mudah sesuai standard pemasangan IUD dan untuk mengetahui keamanannya. Metode: Uji klinis fase II, post test observation. Bahan dan cara: IUD yang dipasang adalah TCu380A d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2019
2019
2020
2020

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 4 publications
0
2
0
1
Order By: Relevance
“…The same for the expulsion rate, the present study was 4.3%, much lower than our previous study which was 9.9% until three months follow up and then increased to 10.6% at six months. 11 Other study reported that PID rate was 1.6 per 1000 women per year 8 , while expulsion rate was 4%. 12,13 A multicenter study using CuT 380A IUD inserted by forceps ring during postpartum period reported expulsion rate 13.8%, 16.6% and20.5% each for the fi rst, third and sixth months follow up, respectively.…”
Section: Discussionmentioning
confidence: 97%
See 1 more Smart Citation
“…The same for the expulsion rate, the present study was 4.3%, much lower than our previous study which was 9.9% until three months follow up and then increased to 10.6% at six months. 11 Other study reported that PID rate was 1.6 per 1000 women per year 8 , while expulsion rate was 4%. 12,13 A multicenter study using CuT 380A IUD inserted by forceps ring during postpartum period reported expulsion rate 13.8%, 16.6% and20.5% each for the fi rst, third and sixth months follow up, respectively.…”
Section: Discussionmentioning
confidence: 97%
“…It was higher compared with expulsion rate reported during interval insertion, but it was not different compared with another study of postpartum IUD insertion. 11 The primary objective of the present study was to compare the safety of CuT 380A IUD inserted by R-inserter and ring forceps during postpartum period, or during the fi rst two hours after delivery of placenta. The secondary objective was to fi nd out the effectiveness (pregnancy rate), and its continuation of use.…”
Section: Abstrakmentioning
confidence: 99%
“…Pada penelitian tersebut penggunaan IUD pascasalin dinyatakan aman, dengan angka infeksi sebesar 1%, keluhan perdarahan 10.1%, dan angka diskontinyu sebanyak 4.8%. 7,8 Konseling IUD pascasalin idealnya dilakukan saat periode asuhan antenatal (AAN). Bila konseling saat AAN tidak kerjakan, maka konseling dapat dilakukan pada: 1) saat memasukkan pasien ke rawat inap 2) saat fase fase laten, 3) saat hari pertama pascasalin, 4) sebelum operasi sesar yang terjadwal.…”