The Use of Mechanical Insufflation-Exsufflation Via Artificial Airways

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
16
0
2

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 23 publications
(18 citation statements)
references
References 23 publications
(28 reference statements)
0
16
0
2
Order By: Relevance
“…A similar study was conducted by Sancho et al 16 They found that S pO 2 , peak inspiratory pressure, mean airway pressure, and work of breathing performed by the ventilator were improved after using MI-E via a tracheostomy tube compared with conventional tracheal suctioning. 10,16 All of the subjects in our study were discharged home without any severe complications from either therapy. In previous reports, complications of MI-E use in adults were rare.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…A similar study was conducted by Sancho et al 16 They found that S pO 2 , peak inspiratory pressure, mean airway pressure, and work of breathing performed by the ventilator were improved after using MI-E via a tracheostomy tube compared with conventional tracheal suctioning. 10,16 All of the subjects in our study were discharged home without any severe complications from either therapy. In previous reports, complications of MI-E use in adults were rare.…”
Section: Discussionmentioning
confidence: 99%
“…8 MI-E works by regularly administering positive pressure to augment inspiration and then negative pressure to enhance expiratory flow. 9,10 The device is effective at increasing cough peak flow for patients with reduced or no capacity to cough and expectorate. 11 Early experiences with MI-E have been effective in adults with neuromuscular weakness, 12 including Duchenne muscular dystrophy 13 and amyotrophic lateral sclerosis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The availability of MI-E devices in Europe since 2002 has increased the number of studies initiated. 25,26 The first team that performed a systematic review on MI-E was Anderson et al 27 in 2005. Their systematic review included 4 controlled trials, with a total of 98 subjects with neuromuscular disease.…”
Section: Introductionmentioning
confidence: 99%
“…2,3 Cough assistance is traditionally based on inspiratory volume increase and manual abdominal thrust and/or chest compression. Mechanically assisted cough devices can also be used for this purpose, with either an endotracheal artificial airway 4 or a mask. 5 These devices sequentially apply positive and negative (subatmospheric) pressure to the airway, creating a pressure gradient to promote a peak expiratory flow (PEF) sufficient to remove secretions from the large airways.…”
Section: Introductionmentioning
confidence: 99%