The Use of Focus-Variation Microscopy for the Assessment of Active Surfaces of a New Generation of Coated Abrasive Tools

Abstract: In this paper, the selected results of measurements and analysis of the active surfaces of a new generation of coated abrasive tools obtained by the use of focus-variation microscopy (FVM) are presented and discussed. The origin of this technique, as well as its general metrological characteristics is briefly described. Additionally, information regarding the focus variation microscope used in the experiments -InfiniteFocus ® IF G4 produced by Alicona Imaging, is also given. The measurements were carried out o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
47
0
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 69 publications
(48 citation statements)
references
References 34 publications
(32 reference statements)
0
47
0
1
Order By: Relevance
“…Figure also shows the depth over the ablated region but it should be noted that some shrinkage of the profilometric samples occurred due to the glutaraldehyde fixation process. The white regions on the 3D images are missing data points which are the limitation of the device where it becomes difficult to receive reflected light signals from the sample areas which have a high slope angle or large height differences in the ablated region . The average depths of 0.55 ± 0.18 and 0.44 ± 0.16 mm are achieved at 18 and 13 J/cm 2 laser fluence, respectively.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure also shows the depth over the ablated region but it should be noted that some shrinkage of the profilometric samples occurred due to the glutaraldehyde fixation process. The white regions on the 3D images are missing data points which are the limitation of the device where it becomes difficult to receive reflected light signals from the sample areas which have a high slope angle or large height differences in the ablated region . The average depths of 0.55 ± 0.18 and 0.44 ± 0.16 mm are achieved at 18 and 13 J/cm 2 laser fluence, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…An Alicona Infinite Focus profilometer is used to examine the depth profile and the 3D surface profile of surgical zone in the tissue sample .…”
Section: Methodsmentioning
confidence: 99%
“…Unlike confocal microscopy, which is regularly used for biological samples and is based on transmitted light, IFM works on reflected light and can therefore be used routinely in quality control and analysis of wear in material engineering and production processes, e.g. measuring metal parts and corrosion [245,246] as well as paper smoothness [247]. This is aided by the large, robust sample stage suitable for items of up to 20 kg [246].…”
Section: Infinite Focus Microscopymentioning
confidence: 99%
“…measuring metal parts and corrosion [245,246] as well as paper smoothness [247]. This is aided by the large, robust sample stage suitable for items of up to 20 kg [246]. In addition to quality control, IFM has been used for the comparison of toolmarks in a forensic context [248,249] as well as the analysis of archaeological and anthropological samples [250][251][252][253][254][255][256] and biological samples that are not amenable to confocal microscopy due to their opacity, such as teeth and bones [257][258][259].…”
Section: Infinite Focus Microscopymentioning
confidence: 99%
“…Para estimar el desgaste de las superficies deslizantes después de los tribo-tests, se llevó a cabo una investigación óptica mediante una adquisición superficial topográfica llevada a cabo con un perfilómetro óptico sin contacto 3D, PLu Neox (Sensofar, Terrassa, España), que funciona como un microscopio confocal [188], [189] o como un interferómetro de luz blanca [190]. Las superficies desgastadas, previamente limpiadas y lavadas con etanol y secadas, se escanearon usando una lente confocal con un aumento de 20x.…”
Section: Figura 6 9: Representación Esquemática Del Aparato Alternativounclassified